콘크리트내로 침투하는 염소이온 반응형 부식센서의 응답특성에 미치는센서 세선 수의 영향에 관한 실험적 연구An Experimental Study on the Effect of Sensor Line Number on the Reactivity Characteristic of Corrosion Sensor Reactive with Chloride Ion to Immigrate into Concrete
- Other Titles
- An Experimental Study on the Effect of Sensor Line Number on the Reactivity Characteristic of Corrosion Sensor Reactive with Chloride Ion to Immigrate into Concrete
- Authors
- 이현석; 이한승
- Issue Date
- May-2014
- Publisher
- 한국구조물진단유지관리공학회
- Keywords
- Corrosion sensor; Electrochemical treatment; Chloride ion; Line of sensor; 부식센서; 전기화학적 측정방법; 염소이온; 세선 수
- Citation
- 한국구조물진단유지관리공학회 논문집, v.18, no.3, pp 143 - 152
- Pages
- 10
- Indexed
- KCI
- Journal Title
- 한국구조물진단유지관리공학회 논문집
- Volume
- 18
- Number
- 3
- Start Page
- 143
- End Page
- 152
- URI
- https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/24997
- DOI
- 10.11112/jksmi.2014.18.3.143
- ISSN
- 2234-6937
2287-6979
- Abstract
- 본 연구에서는 콘크리트내로 침투하는 염소이온을 모니터링하기 위하여, 스크린프리트 기법으로 염소이온 반응형 부식센서를 개발하고,센서의 세선 수가 부식반응도 및 민감도에 미치는 영향을 실험을 통하여 정량적으로 분석하였다. 개발된 부식센서를 이용하여 염소이온량에 따라 부식 반응도을 확인하였으며, 센서의 파괴정도에 따른 저항변화에서는 단선형 센서보다 다선형 센서에서 큰 저항 변화를 나타내었다. 또한, 부식센서는 NaCl 수용액의 농도가 높은 만큼 센서의 저항변화가 크고, 콘크리트 내에서 센서 종류에 따른 부식저항은 단선형보다 다선형에서 민감도가 높게 나타났으며, 센서의 매설깊이가 클수록 저항변화 사이클 (cycle)은 증가하였다.
이상의 결과로, 본 연구에서 개발된 부식센서는 염분에 대한 부식반응과 민감도, 저항의 변화를 감지할 수 있었으며, 특히 7세선이 우수한 결과를 나타내어, 염분의 침투정도를 모니터링 하는데 가장 적합하다고 판단된다.
In this study, the sensor response and sensitivity is experimented and analyzed quantitatively by the line numbers of chlorine ionreaction type corrosion sensor that is developed. The sensor response of the developed corrosion sensor is verified with propertiesof chlorine ion. The multilineal sensor is shown a large resistance change more than the single line sensor by damage of thesensor. And, the resistance change of sensor is as large as high concentration of NaCl aqueous solution, the sensitivity ofmultilineal sensor is higher than single line sensor’s, and the depth of sensor’s location is as large as the increasing of resistancechange time (cycle). These results suggest that, the developed corrosion sensor could sense corrosion reaction, sensor sensitivityand change of resistance for chloride ion. Especially, It was judged that 7 line sensor was the most superior for monitoringchloride ion immigration into concrete.