Experimental and Analytical Study on DC Breakdown Characteristics of Butt Gap Condition in LN2/PPLP Composite System
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Seong, Jae-Kyu | - |
dc.contributor.author | Choi, Won | - |
dc.contributor.author | Shin, Woo-Ju | - |
dc.contributor.author | Hwang, Jae-Sang | - |
dc.contributor.author | Lee, Bang-Wook | - |
dc.date.accessioned | 2021-06-23T03:22:01Z | - |
dc.date.available | 2021-06-23T03:22:01Z | - |
dc.date.issued | 2013-06 | - |
dc.identifier.issn | 1051-8223 | - |
dc.identifier.issn | 1558-2515 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/27944 | - |
dc.description.abstract | Due to ac loss in superconducting materials, high cryogenic costs are inevitable when superconducting devices are operated in ac power networks. Thus, dc electric power networks would be regarded as a better choice for the operation of superconducting devices. In order to develop superconducting devices for a dc network, the dc insulation characteristics, which are much different from the ac insulation characteristics, should be clarified. In this paper, in order to investigate the dc insulation characteristics of polypropylene laminated paper (PPLP), which is generally used for dc superconducting cable, a dc breakdown test and a dc electric field analysis were performed. For the dc breakdown test, specimens with three layers of PPLP with one butt gap were fabricated. In order to reveal the breakdown characteristic of PPLP, a dc electric fields calculation in the media at the moment of breakdown was performed considering capacitive and resistive field distributions. Consequently, the capacitive electric field and resistive electric field distributions were determined using dc field analysis techniques and it was found that the butt gap edge is affected enough by the high field strength to cause the breakdown. Furthermore, it was deduced that the butt gap edge acted as a triple-junction point which causes the breakdown. | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | Institute of Electrical and Electronics Engineers | - |
dc.title | Experimental and Analytical Study on DC Breakdown Characteristics of Butt Gap Condition in LN2/PPLP Composite System | - |
dc.type | Article | - |
dc.publisher.location | 미국 | - |
dc.identifier.doi | 10.1109/TASC.2013.2238593 | - |
dc.identifier.scopusid | 2-s2.0-84874591200 | - |
dc.identifier.wosid | 000318895100156 | - |
dc.identifier.bibliographicCitation | IEEE Transactions on Applied Superconductivity, v.23, no.3 | - |
dc.citation.title | IEEE Transactions on Applied Superconductivity | - |
dc.citation.volume | 23 | - |
dc.citation.number | 3 | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | sci | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Physics | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.relation.journalWebOfScienceCategory | Physics, Applied | - |
dc.subject.keywordAuthor | Breakdown characteristic | - |
dc.subject.keywordAuthor | butt gap | - |
dc.subject.keywordAuthor | dc electric field analysis | - |
dc.subject.keywordAuthor | finite element method (FEM) | - |
dc.subject.keywordAuthor | liquid nitrogen (LN2) | - |
dc.subject.keywordAuthor | poly-propylene laminated paper (PPLP) | - |
dc.subject.keywordAuthor | superconducting cable | - |
dc.identifier.url | https://ieeexplore.ieee.org/document/6407818 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.