Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

RC구조물의 Eddy Current 기반 철근부식 감지 센서에 관한 실험적 연구Experimental Study on Eddy Current based-on Corrosion Detection Sensor for RC structure

Other Titles
Experimental Study on Eddy Current based-on Corrosion Detection Sensor for RC structure
Authors
양현민이한승
Issue Date
May-2019
Publisher
한국건축시공학회
Keywords
철근콘크리트 구조물; 와전류; 철근; 부식; 센서; rc structure; eddy current; rebar; corrosion; sensor
Citation
2019년 한국건축시공학회 춘계학술발표대회 논문집, v.19, no.1, pp 260 - 261
Pages
2
Indexed
OTHER
Journal Title
2019년 한국건축시공학회 춘계학술발표대회 논문집
Volume
19
Number
1
Start Page
260
End Page
261
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/2968
Abstract
Corrosion of rebar embedded reinforced concrete is the main cause of collapse and degradation of reinforced concrete structure that many researches are recently focused on these works. Methods of evaluating rebar corrosion are divided into physical and electrochemical methods. However, the result of Conventional methods are less reliable due to effect of internal and external environments. In this study, rebar corrosion detection sensor for embedded rebar of RC structures is evaluated through immersion test in NaCl solustion for 160hours. From the results, Rebar corrosion was ongoing and corrosion products are produced on rebar surface. The voltage is decreased as amount of corrosion production increased.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > MAJOR IN ARCHITECTURAL ENGINEERING > 1. Journal Articles