Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Anti-corrosion properties of the reactive anode and cathode inhibitor by electrochemical treatment in aqueous

Authors
Lee, HanseungRyu, Hwa Sung
Issue Date
Nov-2013
Publisher
Trans Tech Pub.
Keywords
Anode; Calcium hydroxide; Cathode; Chloride; Corrosion; Electrochemical; Inhibitor
Citation
Applied Mechanics and Materials, v.284-287, pp 31 - 34
Pages
4
Indexed
SCOPUS
Journal Title
Applied Mechanics and Materials
Volume
284-287
Start Page
31
End Page
34
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/30577
DOI
10.4028/www.scientific.net/AMM.284-287.31
ISSN
1660-9336
Abstract
The durability of a concrete structure is most significantly influenced by the corrosion of reinforcing bars, rather than by the deterioration of concrete itself. The corrosion of reinforcement bars due to chloride serves as a main deterioration factor at the interface between the bars and the concrete in the concrete structure. Accordingly, the corrosion inhibitors are widely used to improve the resistance to chloride penetration into reinforced concrete. Corrosion inhibitors are generally divided into the anode-type inorganic inhibitors and anode-cathode-type organic inhibitors, in terms of the reaction type. It is known that when the Cl-:OH- concentration ratio exceeds 0.6%, film on passive state metal on the bar-concrete interface is damaged and local corrosion starts regardless of the chloride ion content. In this study, the performance of the corrosion inhibitor was examined using a potentiostat, with chloride ion contents of 1.2kg/m3 (as reference), 2.4kg/m3, and 4.8kg/m3. The variables were the inhibitor type, Cl-:OH- molar ratio according to the addition of anode-type inorganic corrosion inhibitor (four ratios: 0.0%, 0.3%, 0.6% and 1.2%), and ratio compared to the standard anode-cathode-type organic corrosion inhibitor liquid (four ratios: 0.0, norm 1/2, norm, norm 2 times). As a result, with the anode-type inorganic nitrite corrosion inhibitor, the corrosion inhibition performance was verified with a corrosion potential of -0.30V at a molar ratio of 0.3% or higher when the chloride ion content was 1.2kg/m3, and at a molar ratio of 0.6% or higher when the chloride ion content was 2.4kg/m3 or 4.8kg/m3. With the anode-cathode-type organic corrosion inhibitor, the corrosion inhibition performance was very good at half the standard quantity (0.42kg/m3) regardless of the chloride ion content. From the added corrosion inhibitor quantities, the anode-cathode-type organic corrosion inhibitor had a better corrosion inhibition performance than the anode-type inorganic nitrite corrosion inhibitor. © (2013) Trans Tech Publications, Switzerland.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > MAJOR IN ARCHITECTURAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Han Seung photo

Lee, Han Seung
ERICA 공학대학 (MAJOR IN ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE