Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Electrochemical Determination of Cadmium and Lead on Pristine Single-walled Carbon Nanotube Electrodes

Authors
Minh-Phuong Ngoc BuiLi, Cheng AiHan, Kwi NamXuan-Hung PhamSeong, Gi Hun
Issue Date
Jul-2012
Publisher
JAPAN SOC ANALYTICAL CHEMISTRY
Citation
ANALYTICAL SCIENCES, v.28, no.7, pp 699 - 704
Pages
6
Indexed
SCI
SCIE
SCOPUS
Journal Title
ANALYTICAL SCIENCES
Volume
28
Number
7
Start Page
699
End Page
704
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/32577
DOI
10.2116/analsci.28.699
ISSN
0910-6340
1348-2246
Abstract
A flexible, transparent, single-walled carbon nanotube (SWCNT) film electrode was prepared by vacuum filtering methods, followed by photolithographic patterning of a photoresist polymer on the SWCNT surface. The morphology of the SWCNT film electrode surface was characterized using a field-emission scanning electron microscope coupled to an energy-dispersive X-ray spectrophotometer. The electrodes were successfully used as a mercury-free electrochemical sensor for individual and simultaneous detection of cadmium (Cd2+) and lead (Pb2+) in 0.02 M HCl by square-wave stripping voltammetry. Some important operational parameters, including deposition time, deposition potential, square-wave amplitude, and square wave-frequency were optimized for the detection of Cd2+ and Pb2+. The newly developed sensor showed good linear behavior in the examined concentration. For individual Cd2+ and Pb2+ ion detection, the linear range was found from 0.033 to 0.228 ppm with detection limits of 0.7 ppb (R-2 = 0.985) for Cd2+ and 0.8 ppb (R-2 = 0.999) for Pb2+. For simultaneous detection, the linear range was found from 0.033 to 0.280 ppm with a limit of detection of 2.2 ppb (R-2 = 0.976) and 0.6 ppb (R-2 = 0.996) for Cd2+ and Pb2+, respectively. SWCNT film electrodes offered favorable reproducibility of +/-5.4% and 4.3% for Cd2+ and Pb2+, respectively. The experiments demonstrated the applicability of carbon nanotubes, specifically in the preparation of SWCNT films. The results suggest that the proposed flexible SWCNT film electrodes can be applied as simple, efficient, cost-effective, and/or disposable electrodes for simultaneous detection of heavy metal ions.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF BIONANO ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Seong, Gi Hun photo

Seong, Gi Hun
ERICA 공학대학 (DEPARTMENT OF BIONANO ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE