Comparative Evaluation Between DC and AC Breakdown Characteristic of Dielectric Insulating Materials in Liquid Nitrogen
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Seong, J. K. | - |
dc.contributor.author | Seo, I. J. | - |
dc.contributor.author | Hwang, J. S. | - |
dc.contributor.author | Lee, B. W. | - |
dc.date.accessioned | 2021-06-23T07:19:43Z | - |
dc.date.available | 2021-06-23T07:19:43Z | - |
dc.date.issued | 2012-06 | - |
dc.identifier.issn | 1051-8223 | - |
dc.identifier.issn | 1558-2515 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/32683 | - |
dc.description.abstract | Due to the existence of AC loss in superconducting materials when an alternating voltage is applied, high cryogenic costs are inevitable to operate superconducting devices in AC networks. Therefore applications of superconducting devices in DC electric power networks could be regarded as the optimum choice for superconducting devices, because superconductors show exactly zero resistance to a DC source. Recently, DC superconducting devices such as DC cables have received noticeable attention as DC power transmission lines. In order to develop DC superconducting devices, the DC insulation characteristics in cryogenic liquids should be clarified. However, up to now, limited research has been reported in this field. In this paper, to clarify the different breakdown characteristics of DC and AC applications, various kinds of cryogenic dielectric sheets including Kraft, Kapton (polyimide) and Nomex (polyamide) papers have been prepared. Furthermore, a penetrating breakdown test for three kinds of sheets and turn-to-turn breakdown tests have been performed in liquid nitrogen (LN2). Consequently, it was found that the prepared sheets have shown 1.7-2.7 times higher dielectric strength than those of AC. Moreover, the Nomex and Kraft sheets have shown a remarkable increase in their dielectric strength in liquid nitrogen compared to air. However, the dielectric strength of the Kapton sheet did not show a remarkable increase in liquid nitrogen. From the turn-to-turn breakdown test, it was proved that the dielectric strength has been linearly increased according to the wrapping number of the sheets and that the DC breakdown voltage was 1.1-2.5 times higher than AC. | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | Institute of Electrical and Electronics Engineers | - |
dc.title | Comparative Evaluation Between DC and AC Breakdown Characteristic of Dielectric Insulating Materials in Liquid Nitrogen | - |
dc.type | Article | - |
dc.publisher.location | 미국 | - |
dc.identifier.doi | 10.1109/TASC.2011.2178222 | - |
dc.identifier.scopusid | 2-s2.0-84862582788 | - |
dc.identifier.wosid | 000307364700497 | - |
dc.identifier.bibliographicCitation | IEEE Transactions on Applied Superconductivity, v.22, no.3 | - |
dc.citation.title | IEEE Transactions on Applied Superconductivity | - |
dc.citation.volume | 22 | - |
dc.citation.number | 3 | - |
dc.type.docType | Article; Proceedings Paper | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | sci | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Physics | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.relation.journalWebOfScienceCategory | Physics, Applied | - |
dc.subject.keywordAuthor | DC insulator | - |
dc.subject.keywordAuthor | dielectric breakdown | - |
dc.subject.keywordAuthor | dielectric materials | - |
dc.subject.keywordAuthor | superconducting material | - |
dc.identifier.url | https://ieeexplore.ieee.org/document/6096389 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.