다충 배선에서의 Quasi-3D 커페시던스 추출
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 어영선 | - |
dc.date.accessioned | 2021-06-23T07:58:35Z | - |
dc.date.available | 2021-06-23T07:58:35Z | - |
dc.date.issued | 1999-11-01 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/33477 | - |
dc.description.abstract | A new accurate as well as efficient multi-layer interconnect capacitance extraction method is presented. Since Multi-layer interconnects is too complicated to directly extract capacitances. It is simplified with virtual ground concept. To make the structure tractable, the shielding effects should be separately determined. Since the electric field shielding effects and the solid-ground-based capacitance matrices can be readily determined from the layout geometry, the accurate as well as efficient quasi-3D capacitances concerned with an objective line can be readily determined. In order to demonstrate its efficiency and accuracy, the parameters and circuit responses were benchmarked with 3D-field-solver-based results. | - |
dc.title | 다충 배선에서의 Quasi-3D 커페시던스 추출 | - |
dc.type | Conference | - |
dc.citation.conferenceName | 전자공학회 추계 학술대회 | - |