Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Effects of Display Curvature, Presbyopia, and Task Duration on Visual Fatigue, Task Performance, and User Satisfaction

Authors
Choi, DongheeKyung, GyouhyungNam, KyunghyunPark, Sungryul
Issue Date
Mar-2019
Publisher
SAGE PUBLICATIONS INC
Keywords
curved display; visual display terminal (VDT) task; presbyope; nonpresbyope; proofreading
Citation
HUMAN FACTORS, v.61, no.2, pp.273 - 287
Indexed
SCIE
SSCI
SCOPUS
Journal Title
HUMAN FACTORS
Volume
61
Number
2
Start Page
273
End Page
287
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/3472
DOI
10.1177/0018720818801407
ISSN
0018-7208
Abstract
Objective: This study examined the effects of display curvature, presbyopia, and task duration on visual fatigue, task performance, and user satisfaction. Background: Although curved displays have been applied to diverse display products, and some studies reported their benefits, it is still unknown whether the effects of display curvature are presbyopia-specific. Method: Each of 64 individuals (eight nonpresbyopes and eight presbyopes per display curvature) performed four 15-min proofreading tasks at one display curvature radius setting (600R, 1140R, 4000R, and flat; mm). Diverse measurements were obtained to assess visual fatigue, task performance, and user satisfaction. Results: The mean pupil diameter was the largest with 1140R, indicating this curvature radius was associated with the least development of visual fatigue; 600R was comparable with 1140R in terms of pupil diameter. The presbyopic group showed a 28.5% slower proofreading speed compared with the nonpresbyopic group, whereas their proofreading accuracy was comparable. For both groups, the mean visual fatigue increased significantly during the first 15 min of proofreading, as indicated by a decrease of 0.11 mm in the mean pupil diameter, an increase of 3.8 in the mean bulbar conjunctival redness, and an increase of 9.13 in the mean eye complaint questionnaire score. Conclusion: The effect of display curvature was not presbyopia-specific. Low visual fatigue was observed with 1140R and 600R. Application: Display curvature radii near or in the range of 600R and 1140R and frequent breaks are recommended for both presbyopic and nonpresbyopic groups to reduce their visual fatigue due to visual display terminal tasks.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF COMPUTING > SCHOOL OF MEDIA, CULTURE, AND DESIGN TECHNOLOGY > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kyung, Gyou hyung photo

Kyung, Gyou hyung
COLLEGE OF COMPUTING (SCHOOL OF MEDIA, CULTURE, AND DESIGN TECHNOLOGY)
Read more

Altmetrics

Total Views & Downloads

BROWSE