Electrochemical endotoxin sensors based on TLR4/MD-2 complexes immobilized on gold electrodes

Authors
Yeo, Tae YunChoi, Ji SukLee, Byung KookKim, Beob SooYoon, Hwa InLee, Hyeong YunCho, Yong Woo
Issue Date
Oct-2011
Publisher
ELSEVIER ADVANCED TECHNOLOGY
Keywords
Electrochemical sensor; Endotoxin; TLR4/MD-2 complex; Gold electrode
Citation
BIOSENSORS & BIOELECTRONICS, v.28, no.1, pp.139 - 145
Indexed
SCIE
SCOPUS
Journal Title
BIOSENSORS & BIOELECTRONICS
Volume
28
Number
1
Start Page
139
End Page
145
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/36518
DOI
10.1016/j.bios.2011.07.010
ISSN
0956-5663
Abstract
Even low concentrations of endotoxins can be life-threatening. As such, continuous effort has been directed toward the development of sensitive and specific endotoxin detection systems. In this paper, we report the design and fabrication of a new electrochemical endotoxin sensor based on a human recombinant toll-like receptor 4 (rhTLR4) and myeloid differentiation-2 (MD-2) complex. The rhTLR4/MD-2 complex, which specifically binds to endotoxin, was immobilized on gold electrodes through a self-assembled monolayer (SAM) technique involving the use of dithiobis(succinimidyl undecanoate) (DSU). The surface topography of the electrodes at each fabrication stage was characterized with a nanosurface profiler and atomic force microscope (AFM). The electrochemical signals generated from interactions between the rhTLR4/MD-2 complex and the endotoxin were characterized by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). A linear relationship between the peak current and endotoxin concentration was obtained in the range of 0.0005 to 5 EU/mL with a correlation coefficient (R(2)) of 0.978. The estimated limit of detection (LOD) was fairly low, 0.0002 EU/mL The rhTLR4/MD-2 based sensors exhibited no current responses to dipalmitoylphosphatidylcholine (DPPC) bearing two lipid chains, which is structurally similar to endotoxin, indicating the high specificity of the sensors to endotoxin. (C) 2011 Elsevier B.V. All rights reserved.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF MATERIALS SCIENCE AND CHEMICAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Cho, Yong Woo photo

Cho, Yong Woo
ERICA 공학대학 (DEPARTMENT OF MATERIALS SCIENCE AND CHEMICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE