Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Influence of PM fouling on effectiveness of heat exchanges in a diesel engine with fin-type EGR coolers of different sizes

Authors
Park, SangkiChoi, KapseungKim, HyungmanLee, Kihyung
Issue Date
Dec-2010
Publisher
SPRINGER
Citation
HEAT AND MASS TRANSFER, v.46, no.11-12, pp.1221 - 1227
Indexed
SCIE
SCOPUS
Journal Title
HEAT AND MASS TRANSFER
Volume
46
Number
11-12
Start Page
1221
End Page
1227
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/39319
DOI
10.1007/s00231-010-0652-0
ISSN
0947-7411
Abstract
The particulate matter (PM) fouling in exhaust gas recirculation (EGR) coolers degrades the heat transfer performance considerably, which in turn has a significant influence on the design of the EGR cooler. To investigate the effects of PM fouling on the heat exchange effectiveness in the fin-type EGR coolers of six different sizes, engine dynamometer experiments were performed. The experimental results show that the heat exchange effectiveness varies with the size of the fin-type EGR cooler.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF MECHANICAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher LEE, KI HYUNG photo

LEE, KI HYUNG
ERICA 공학대학 (DEPARTMENT OF MECHANICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE