Effect of distance between 90 degrees elbow close to upstream of orifice plate and the orifice plate on discharge coefficient

Authors
Yoon, J. Y.Sung, N. W.Lee, C. H.
Issue Date
May-2009
Publisher
SAGE PUBLICATIONS LTD
Keywords
differential pressure; discharge coefficient; orifice plate; elbow
Citation
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, v.223, no.2, pp.97 - 100
Indexed
SCIE
SCOPUS
Journal Title
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING
Volume
223
Number
2
Start Page
97
End Page
100
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/41261
DOI
10.1243/09544089JPME197
ISSN
0954-4089
Abstract
The effect of distance between 90 degrees elbow close to the upstream face of an orifice plate and the orifice plate on discharge coefficient was investigated. The distribution of discharge coefficient and differential pressure caused by elbow and short upstream straight length were examined and a modified discharge coefficient was introduced. The results presented in this study could be useful when the orifice plate is installed under the condition of simple flow disturbance element and short upstream straight length.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF MECHANICAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher YOON, JOON YONG photo

YOON, JOON YONG
ERICA 공학대학 (DEPARTMENT OF MECHANICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE