Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Preparation of Linear Low Density Polyethylene/Poly(ethylene-co-vinyl acetate) Blend Films with Various Transparencies

Authors
Kwak, Kun YoungLee, Young JaeOh, Kyeong IlSong, Du HyunShin, Eun JooJeon, Han YongGal, Yeong SoonOh, Tae HwanHan, Sung SooChoi, Han GonLee, Yong RokNoh, Seok KyunLyoo, Won Seok
Issue Date
Nov-2009
Publisher
SAGE PUBLICATIONS LTD
Citation
POLYMERS & POLYMER COMPOSITES, v.17, no.9, pp.575 - 580
Indexed
SCIE
SCOPUS
Journal Title
POLYMERS & POLYMER COMPOSITES
Volume
17
Number
9
Start Page
575
End Page
580
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/41815
DOI
10.1177/096739110901700906
ISSN
0967-3911
Abstract
Linear low density polyethylene (LLDPE)/poly(ethylene-co-vinyl acetate) (EVAc) blend films having various vinyl acetate (VAc) contents (12, 18, and 25 wt.%) with various degrees of transparency were prepared using a hot plate press. Effects of VAc contents in EVAc and ratio of EVAc in LLDPE/EVAc blend films on the structure and properties of these films were investigated through a series of instrumental analyses. The transparencies of films were classified into three types: non-transparent (1-75 T(%)), semi-transparent (76-85 T(%)), and transparent (86-100 T(%)). With increasing the contents of VAc in EVAc and the ratio of EVAc in blend films, the transparencies of films were increased. The differential scanning calorimeter curves of blend films show that there are two obvious endothermic peaks at around 125 and 75-85 degrees C, which corresponded to the melting of the LLDPE and EVAc crystals, respectively. The intensity of crystalline peaks of LLDPE decreased as the ratio of EVAc in blend films was increased. The thermal stability of blend film decreased with increasing degree of transparency. This might be due to the fact that transparent film can contain higher amount of amorphous regions, which were degraded at lower temperature than that of non-transparent films having high contents of crystalline regions. The storage modulus of non-transparent films was higher than that of semi-transparent films due to a higher crystallinity.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF PHARMACY > DEPARTMENT OF PHARMACY > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Han Gon photo

Choi, Han Gon
COLLEGE OF PHARMACY (DEPARTMENT OF PHARMACY)
Read more

Altmetrics

Total Views & Downloads

BROWSE