Discharge coefficient equation of a segmental wedge flowmeter
- Authors
- Yoon, J. Y.; Sung, N. W.; Lee, C. H.
- Issue Date
- Feb-2008
- Publisher
- SAGE PUBLICATIONS LTD
- Keywords
- segmental wedge; discharge coefficient; wedge flowmeter; Reynolds number
- Citation
- PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, v.222, no.1, pp 79 - 83
- Pages
- 5
- Indexed
- SCIE
SCOPUS
- Journal Title
- PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING
- Volume
- 222
- Number
- 1
- Start Page
- 79
- End Page
- 83
- URI
- https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/42676
- DOI
- 10.1243/09544089JPME121
- ISSN
- 0954-4089
2041-3009
- Abstract
- The discharge coefficient is reported for a flowmeter based on a segmental wedge device having a vertex angle of 90 degrees for varying ratios of pipe diameter D to characteristic free flow dimension H at the wedge. The current work suggests that the segmental wedge makes a reliable flow-metering device, with a near constant discharge coefficient over a wide range of Reynolds numbers. A correlation is provided for the discharge coefficient as a function of HID.
- Files in This Item
-