Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Gold nanoparticle aggregation-based highly sensitive DNA detection using atomic force microscopy

Authors
Bui, Minh-Phuong NgocBaek, Taek JinSeong, Gi Hun
Issue Date
Jul-2007
Publisher
SPRINGER HEIDELBERG
Keywords
AFM; gold nanoparticles; sandwich DNA hybridization; DNA detection
Citation
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, v.388, no.5-6, pp 1185 - 1190
Pages
6
Indexed
SCIE
SCOPUS
Journal Title
ANALYTICAL AND BIOANALYTICAL CHEMISTRY
Volume
388
Number
5-6
Start Page
1185
End Page
1190
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/43585
DOI
10.1007/s00216-007-1354-4
ISSN
1618-2642
1618-2650
Abstract
The potential ability of atomic force microscopy (AFM) as a quantitative bioanalysis tool is demonstrated by using gold nanoparticles as a size enhancer in a DNA hybridization reaction. Two sets of probe DNA were functionalized on gold nanoparticles and sandwich hybridization occurred between two probe DNAs and target DNA, resulting in aggregation of the nanoparticles. At high concentrations of target DNA in the range from 100 nM to 10 mu M, the aggregation of gold nanoparticles was determined by monitoring the color change with UV-vis spectroscopy. The absorption spectra broadened after the exposure of DNA-gold nanoparticles to target DNA and a new absorption band at wavelengths > 600 nm was observed. However, no differences were observed in the absorption spectra of the gold nanoparticles at low concentrations of target DNA (10 pM to 10 nM) due to insufficient aggregation. AFM was used as a biosensing tool over this range of target DNA concentrations in order to monitor the aggregation of gold nanoparticles and to quantify the concentration of target DNA. Based on the AFM images, we successfully evaluated particle number and size at low concentrations of target DNA. The calibration curve obtained when mean particle aggregate diameter was plotted against concentration of target DNA showed good linearity over the range 10 pM to 10 nM, the working range for quantitative target DNA analysis. This AFM-based DNA detection technique was three orders of magnitude more sensitive than a DNA detection method based on UV-vis spectroscopy.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF BIONANO ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Seong, Gi Hun photo

Seong, Gi Hun
ERICA 공학대학 (DEPARTMENT OF BIONANO ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE