LIF 공초점 현미경을 이용한 장애물이 있는 Y-채널 마이크로믹서의 최적설계 평가
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 현석호 | - |
dc.contributor.author | 이도형 | - |
dc.contributor.author | 이성수 | - |
dc.contributor.author | 전재연 | - |
dc.date.accessioned | 2021-06-23T21:04:25Z | - |
dc.date.available | 2021-06-23T21:04:25Z | - |
dc.date.issued | 2006-11 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/44546 | - |
dc.description.abstract | Owing to the extremely small device and velocity scale, mixing in microchannel proceeds very slowly by way of molecular diffusion transport. Thus mixing enhancement becomes a central issue in microfluidics for biomedical and chemical applications. In this work, we evaluate the simulation result of optimization procedure through experiment and fabrication. In efficient micromixer design, it is essential to evaluate mixing efficiency with good precision. Mixing efficiency for Y-channel micromixer is measured by fluorescence intensity using LIF(Laser Induced Fluorescence) Confocal Microscope. The Y-channel micromixers are fabricated with polydimethylsiloxane(PDMS). Nile Blue A is injected into the micromixer as a fluorescence dye for measuring of fluorescence intensity by He/Ne laser. Throughout the experiments and computer simulation, accurate mixing efficiency evaluation process for a PDMS Y-channel micromixer is established. | - |
dc.format.extent | 6 | - |
dc.language | 한국어 | - |
dc.language.iso | KOR | - |
dc.publisher | 대한기계학회 | - |
dc.title | LIF 공초점 현미경을 이용한 장애물이 있는 Y-채널 마이크로믹서의 최적설계 평가 | - |
dc.title.alternative | Optimum Design Evaluation in Y-channel Micromixer using LIF Conforcal Microscope | - |
dc.type | Article | - |
dc.publisher.location | 대한민국 | - |
dc.identifier.bibliographicCitation | 대한기계학회 추계학술대회 논문집 , v.2006, no.11, pp 6 - 11 | - |
dc.citation.title | 대한기계학회 추계학술대회 논문집 | - |
dc.citation.volume | 2006 | - |
dc.citation.number | 11 | - |
dc.citation.startPage | 6 | - |
dc.citation.endPage | 11 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | other | - |
dc.subject.keywordAuthor | Microchannel(마이크로 채널) | - |
dc.subject.keywordAuthor | Optimum Design(최적설계) | - |
dc.subject.keywordAuthor | LIF Conforcal Microscope(공초점 레이저 유발 형광 현미경) | - |
dc.identifier.url | https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE00853510 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.