Reduction of radiation exposure to operating physician and assistant using a real-time auditory feedback dosimeter during femoral artery puncturing: a study on swine modelopen access

Authors
Khan, Muhammad Umair AhmadYi, Byung ju
Issue Date
2019
Publisher
SpringerOpen
Keywords
Fluoroscopy; Occupational exposure; Radiation exposure; Radiation protection; Radiometry
Citation
European Radiology Experimental, v.3, no.1, pp.1 - 6
Indexed
SCIE
SCOPUS
Journal Title
European Radiology Experimental
Volume
3
Number
1
Start Page
1
End Page
6
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/4625
DOI
10.1186/s41747-019-0116-3
ISSN
2509-9280
Abstract
Background: Real-time dosimeters may create a relatively safer environment not only for the patient but also for the physician and the assistant as well. We propose the use of a real-time radiation measurement dosimeter having auditory feedback to reduce radiation exposure. Methods: Radiation dose rates were measured for 30 fluoroscopy-guided puncturing procedures of femoral arteries in swine. Fifteen puncturing procedures were performed with real-time radiation measurement dosimeter having auditory feedback and other 15 were performed without auditory feedback dosimeter by an interventional cardiologist with 10 years of experience. Results: The left body side of the operating physician (38%, p < 0.001) and assistant (25%, p < 0.001) was more exposed as compared to the right body side. Radiation dose rate to the left hand, left arm and left leg were reduced from 0.96 ± 0.10 to 0.79 ± 0.12 mSv/h (17% reduction, p < 0.001), from 0.11 ± 0.02 to 0.07 ± 0.01 mSv/h (36% reduction, p < 0.001) and from 0.22 ± 0.06 to 0.15 ± 0.02 mSv/h (31% reduction, p < 0.001) with the use of auditory feedback dosimeter, respectively. The mean fluoroscopic time was reduced from 4.8 ± 0.43 min to 4.2 ± 0.53 min (p < 0.001). The success rate of performing arterial puncturing was 100%. Conclusions: The use of auditory feedback dosimeter resulted in reduction in effective dose. The sound beep alerted the physician from the danger of exposure, and this approach induced awareness and protective mindset to the operating physician and assistant. © 2019, The Author(s).
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > SCHOOL OF ELECTRICAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yi, Byung Ju photo

Yi, Byung Ju
ERICA 공학대학 (SCHOOL OF ELECTRICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE