Analysis of Transient Behavior of Mixed High Voltage DC Transmission Line Under Lightning Strikes
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Asif, Mansoor | - |
dc.contributor.author | Lee, Ho-Yun | - |
dc.contributor.author | Khan, Umer Amir | - |
dc.contributor.author | Park, Kyu-Hoon | - |
dc.contributor.author | Lee, Bang-Wook | - |
dc.date.accessioned | 2021-06-22T11:02:23Z | - |
dc.date.available | 2021-06-22T11:02:23Z | - |
dc.date.issued | 2019-01 | - |
dc.identifier.issn | 2169-3536 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/4627 | - |
dc.description.abstract | Growing urbanization coupled with increased power demands have led to increasing use of mixed power transmission lines with sections of overhead lines (OHL) and underground cables. Due to differences in surge impedance of cables and OHL, voltage surges experience reflections and refractions at their boundaries which make the transient behavior of mixed high voltage direct current (HVDC) line quite peculiar. Lightning strikes on overhead sections of lines induce voltage surges that travel along OHL and enter the cable section. Lightning overvoltage can cause OHL insulators to flashover and stress cable insulation or cause its permanent breakdown. In this paper, we simulated a fast front model of a mixed HVDC transmission line using an electromagnetic transient simulation program (PSCAD) to analyze its transient behavior under a lightning strike. The leader progression model has been used to predict the dielectric performance of OHL insulators. It has been shown that transition towers adjacent to the cable section are much less vulnerable to flashover than subsequent towers. The length of a riser section (connecting OHL and cable) and tower footing impedance have shown to significantly influence the flashover performance of OHL insulators. In addition, the length of cable segments and sheath grounding impedance has been found to influence cable overvoltage. This paper can be used to evaluate the insulation coordination and overvoltage protection requirements for a mixed HVDC transmission line. | - |
dc.format.extent | 12 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | Institute of Electrical and Electronics Engineers Inc. | - |
dc.title | Analysis of Transient Behavior of Mixed High Voltage DC Transmission Line Under Lightning Strikes | - |
dc.type | Article | - |
dc.publisher.location | 미국 | - |
dc.identifier.doi | 10.1109/ACCESS.2018.2889828 | - |
dc.identifier.scopusid | 2-s2.0-85059254348 | - |
dc.identifier.wosid | 000456909400001 | - |
dc.identifier.bibliographicCitation | IEEE Access, v.7, pp 7194 - 7205 | - |
dc.citation.title | IEEE Access | - |
dc.citation.volume | 7 | - |
dc.citation.startPage | 7194 | - |
dc.citation.endPage | 7205 | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | Y | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Computer Science | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Telecommunications | - |
dc.relation.journalWebOfScienceCategory | Computer Science, Information Systems | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.relation.journalWebOfScienceCategory | Telecommunications | - |
dc.subject.keywordPlus | SYSTEMS | - |
dc.subject.keywordPlus | MODELS | - |
dc.subject.keywordAuthor | DC cable | - |
dc.subject.keywordAuthor | dielectric breakdown | - |
dc.subject.keywordAuthor | HVDC transmission | - |
dc.subject.keywordAuthor | insulation coordination | - |
dc.subject.keywordAuthor | insulator flashover | - |
dc.subject.keywordAuthor | lightning overvoltage | - |
dc.subject.keywordAuthor | negative lightning strokes | - |
dc.subject.keywordAuthor | parametric analysis | - |
dc.subject.keywordAuthor | PSCAD/EMTDC | - |
dc.subject.keywordAuthor | sheath grounding | - |
dc.identifier.url | https://ieeexplore.ieee.org/document/8590704/ | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.