Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Experimental investigation of the thermal and disinfection performances of a novel hydrodynamic cavitation reactor

Authors
Sun, XunPark, Jong JinKim, Hyun SooLee, Seung HoSeong, Si JinOm, Ae SonYoon, Joon Yong
Issue Date
Dec-2018
Publisher
ELSEVIER SCIENCE BV
Keywords
Hydrodynamic cavitation; Water disinfection; Escherichia coli; Treatment rate; Thermal performance; Economy
Citation
ULTRASONICS SONOCHEMISTRY, v.49, pp.13 - 23
Indexed
SCIE
SCOPUS
Journal Title
ULTRASONICS SONOCHEMISTRY
Volume
49
Start Page
13
End Page
23
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/5051
DOI
10.1016/j.ultsonch.2018.02.039
ISSN
1350-4177
Abstract
In the present study, we proposed an effective, efficient, and economical approach to disinfect water using a novel, advanced, rotational hydrodynamic cavitation reactor (HCR). First, analyses of the flow field and cavitation generation mechanism in the HCR were conducted through visualization of the reactor flow field using a high-speed camera. Second, the thermal performance was tested in 20 experiments with various rotational speeds of the rotor (2700, 3000, 3300, and 3600 rpm) and pump pressure settings (0.0, 0.5, 0.7, 1.0, and 1.5 bar gauge pressure). The HCR maximally achieved a heat generation rate of 48.15 MJ/h and thermal efficiency of 82.18%. Then, the disinfection effect was evaluated using water that simulated an effluent containing Escherichia coli (E. coli) for various flow rates (8, 11, and 14 L/min), a pump pressure setting fixed at 0.5 bar, and a rotational speed of 3600 rpm. In addition, an economical assessment of the disinfection processes was performed by considering the measured electric consumption. The thermal effect generated by the HCR was the dominant factor affecting the concentration of E. coll. The HCR achieved a 100% disinfection rate with a 4.3 L/min treatment rate and a cost of US $ 3.019/m(3) at the optimal flow rate. The effects of the pressure setting and rotational speed on the performance were discussed in detail. Finally, compared to the recent studies, the treatment rate of the HCR is several hundred times greater than that obtained by the HCRs utilized in those studies, and also has a reasonable cost.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF MECHANICAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher YOON, JOON YONG photo

YOON, JOON YONG
ERICA 공학대학 (DEPARTMENT OF MECHANICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE