Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Reliable quantification of trace diarrhetic shellfish poisoning toxins in high-lipid bivalves by UHPLC-ESI-MS/MS in time segment polarity switching mode: Comparison of three extraction methods

Authors
Lee, Myoung EunKo, Keon-heePark, Na-HyunLee, WonwoongYoo, Hye HyunLee, JeongmiChoi, Yong SeokHong, Jongki
Issue Date
Dec-2018
Publisher
Elsevier BV
Keywords
High-lipid bivalves; Diarrhetic toxins; Freezing-lipid filtration; Mobile phase aging; Time segment polarity switching; UHPLC-ESI-MS/MS
Citation
Microchemical Journal, v.143, pp.441 - 449
Indexed
SCIE
SCOPUS
Journal Title
Microchemical Journal
Volume
143
Start Page
441
End Page
449
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/5059
DOI
10.1016/j.microc.2018.08.043
ISSN
0026-265X
Abstract
Analysis of marine biotoxins in high-lipid bivalves has several limitations due to the coexistence of lipid matrices, low biotoxin concentrations, and the different physiochemical properties of the various biotoxins. In this study, a sensitive and reliable method to simultaneously determine six diarrhetic shellfish poisoning (DSP) toxins (five acidic and one neutral biotoxins) in oysters and mussels was developed based on UHPLC-MS/MS-multiple ion reaction monitoring (MRM) using time segment polarity switching. For effective sample pretreatment, three protocols including syringe filtration, Strata (TM)-X solid phase extraction (SPE), and freezing lipid filtration combined with SPE (FLF + SPE) were evaluated, and FLF + SPE method was shown to be the most effective with high lipid removal efficiency. Aging effects of the UHPLC mobile phase on MS detection sensitivity and retention time shift of DSP toxins were carefully examined. The developed method provided good recoveries ranging from 81.0 to 119.6%, showing no significant matrix effect and assay was linear with coefficients of determination above R-2 > 0.99 for all analytes. Validation tests using a certified reference material (CRM) and spiking DSP toxins (OA and DTX-1 at 1.07 mu g/g, and DTX-2 at 0.86 mu g/g) showed this method to be acceptable, with a relative standard deviation of < 0.17% and recovery ranging from 87.29 to 109.97%. Finally, the established method was successfully applied to quantify DSP toxins in 40 oyster and mussel samples collected from Korean fishery markets, ensuring sea food safety.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF PHARMACY > DEPARTMENT OF PHARMACY > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoo, Hye Hyun photo

Yoo, Hye Hyun
COLLEGE OF PHARMACY (DEPARTMENT OF PHARMACY)
Read more

Altmetrics

Total Views & Downloads

BROWSE