Assessment of Appropriate MMC Topology Considering DC Fault Handling Performance of Fault Protection Devices
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Ho-Yun | - |
dc.contributor.author | Asif, Mansoor | - |
dc.contributor.author | Park, Kyu-Hoon | - |
dc.contributor.author | Lee, Bang-Wook | - |
dc.date.accessioned | 2021-06-22T11:23:16Z | - |
dc.date.available | 2021-06-22T11:23:16Z | - |
dc.date.issued | 2018-10 | - |
dc.identifier.issn | 2076-3417 | - |
dc.identifier.issn | 2076-3417 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/5288 | - |
dc.description.abstract | D The eventual goal of high-voltage direct-voltage (HVDC) systems is to implement HVDC grids. The modular multilevel converter (MMC) has been identified as the best candidate for the realization of an HVDC grid by eliminating the shortcomings of conventional voltage source converter (VSC) technology. The related research has focused on efficient control schemes, new MMC topologies, and operational characteristics of an MMC in a DC grid, but there is little understanding about the fault handling capability of two mainstream MMC topologies, i.e., half bridge (HB) and full bridge (FB) MMCs in combination with an adequate protection device. Contrary to the existing research where the fault location is usually fixed (center of the line), this paper considered a variable fault location on the DC line, so as to compare the fault interruption time and maximum fault current magnitude. From the point of view of fault interruption, AC and DC side transient analyses were performed for both MMC topologies to suggest the appropriate topology. The simulation result confirmed that the fault handling performance of an HB-MMC with a DC circuit breaker is superior due to the smaller fault current magnitude, faster interruption time, lower overvoltage magnitude, and lesser stresses on the insulation of the DC grid. | - |
dc.format.extent | 15 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | MDPI | - |
dc.title | Assessment of Appropriate MMC Topology Considering DC Fault Handling Performance of Fault Protection Devices | - |
dc.type | Article | - |
dc.publisher.location | 스위스 | - |
dc.identifier.doi | 10.3390/app8101834 | - |
dc.identifier.scopusid | 2-s2.0-85054490650 | - |
dc.identifier.wosid | 000448653700129 | - |
dc.identifier.bibliographicCitation | Applied Sciences-basel, v.8, no.10, pp 1 - 15 | - |
dc.citation.title | Applied Sciences-basel | - |
dc.citation.volume | 8 | - |
dc.citation.number | 10 | - |
dc.citation.startPage | 1 | - |
dc.citation.endPage | 15 | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | Y | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Materials Science | - |
dc.relation.journalResearchArea | Physics | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Multidisciplinary | - |
dc.relation.journalWebOfScienceCategory | Engineering, Multidisciplinary | - |
dc.relation.journalWebOfScienceCategory | Materials Science, Multidisciplinary | - |
dc.relation.journalWebOfScienceCategory | Physics, Applied | - |
dc.subject.keywordPlus | HVDC | - |
dc.subject.keywordAuthor | half bridge (HB) | - |
dc.subject.keywordAuthor | full bridge (FB) | - |
dc.subject.keywordAuthor | modular multilevel converter (MMC) | - |
dc.subject.keywordAuthor | hybrid HVDC breaker (HCB) | - |
dc.identifier.url | https://www.mdpi.com/2076-3417/8/10/1834 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.