Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Development and Metrological Evaluation of a Force Transducer for Industrial Applicationopen access

Authors
Singh, Ajay PratapGhoshal, Sanjoy K.Kumar, HarishYoon, JonghunYadav, Poonam
Issue Date
Jan-2021
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Keywords
Force; Transducers; Force measurement; Pollution measurement; Strain; Biomedical measurement; Stress; Finite element analysis (FEA); ISO 376; 2011; metrological evaluation; square ring force transducer (SRFT); strain gauge
Citation
IEEE ACCESS, v.9, pp.33299 - 33312
Indexed
SCIE
SCOPUS
Journal Title
IEEE ACCESS
Volume
9
Start Page
33299
End Page
33312
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/620
DOI
10.1109/ACCESS.2021.3060746
ISSN
2169-3536
Abstract
The present investigation reports the development of a force transducer for industrial applications with facile design and manufacturing objectives. The design of the force transducer is based on the analytical and computational approaches, followed by the experimental verification. Factors such as stress, strain and deflection of the force transducer were evaluated while conducting a rigorous assessment of the proposed force transducer. Al 7075 (T6) grade of aluminum alloy has been used as the material for fabrication of the force transducer with a nominal capacity of 2 kN. The fabricated force transducer as per the proposed design has also been investigated for geometrical and dimensional accuracy using precision coordinate measuring machine (CMM). Metrological characterization as per ISO 376: 2011 revealed that uncertainty of measurements is within 0.05 %, which includes relative uncertainty of the force transducer the factors such as repeatability, reproducibility, reversibility, interpolation, resolution, zero offset. Based on the above investigations, it has been found that the designed force transducer is of low cost ($ 200-$ 300), ease to manufacturing, and precise enough (0.05 % uncertainty of measurement) force transducer for force measurement up to 2 kN. The developed force transducer offers sensitivity up to of 0.2 N or better.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF MECHANICAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoon, Jong hun photo

Yoon, Jong hun
ERICA 공학대학 (DEPARTMENT OF MECHANICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE