Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Correlation between Partial Discharge Inception Voltage and Breakdown Voltage Characteristics of Butt-gap in HVDC Mass Impregnated PPLP Cable

Full metadata record
DC Field Value Language
dc.contributor.authorOh, Dong hun-
dc.contributor.authorLee, Ho young-
dc.contributor.authorKim, Sun jin-
dc.contributor.authorLee, Bang wook-
dc.date.accessioned2021-06-22T13:03:26Z-
dc.date.available2021-06-22T13:03:26Z-
dc.date.issued2018-10-
dc.identifier.issn0084-9162-
dc.identifier.issn2576-2397-
dc.identifier.urihttps://scholarworks.bwise.kr/erica/handle/2021.sw.erica/7975-
dc.description.abstractThe voids are formed inside the butt-gap in the HVDC Mass Impregnated PPLP (MI PPLP) cable since the thermal contraction of the mass is about ten times larger than PPLP. When the DC voltage applied to the MI PPLP cable is above partial discharge inception voltage (PDIV), partial discharge occurs in the void. The continued partial discharge accelerates electrical ageing and breakdown may occur as a result. Hence, it is necessary to study the correlation between partial discharge inception and breakdown in DC steady state. Partial discharge and breakdown in the DC steady state are affected by the temperature and the polarity of the applied voltage. Therefore, in this paper, to analyze the correlation between PDIV and Breakdown Voltage (BDV) of butt-gap in HVDC MI PPLP cable, BDV and PDIV measurement were performed according to temperatures of the specimen and polarities of the applied voltage. From the experimental results, The BDV of the butt-gap in the MI PPLP was found to be inversely proportional to the conductivity and proportional to PDIV. Also, PDIV and BDV were higher at negative voltage compared to positive polarity voltage. Consequently, BDV can be predicted through the temperature of the MI-PPLP and PDIV. © 2018 IEEE.-
dc.format.extent4-
dc.language영어-
dc.language.isoENG-
dc.publisherInstitute of Electrical and Electronics Engineers Inc.-
dc.titleCorrelation between Partial Discharge Inception Voltage and Breakdown Voltage Characteristics of Butt-gap in HVDC Mass Impregnated PPLP Cable-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1109/CEIDP.2018.8544729-
dc.identifier.scopusid2-s2.0-85059735309-
dc.identifier.bibliographicCitationAnnual Report - Conference on Electrical Insulation and Dielectric Phenomena, CEIDP, v.2018, pp 518 - 521-
dc.citation.titleAnnual Report - Conference on Electrical Insulation and Dielectric Phenomena, CEIDP-
dc.citation.volume2018-
dc.citation.startPage518-
dc.citation.endPage521-
dc.type.docTypeConference Paper-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassother-
dc.subject.keywordPlusCables-
dc.subject.keywordPlusElectric breakdown-
dc.subject.keywordPlusHVDC power transmission-
dc.subject.keywordPlusApplied voltages-
dc.subject.keywordPlusElectrical ageing-
dc.subject.keywordPlusNegative voltage-
dc.subject.keywordPlusPartial discharge inception-
dc.subject.keywordPlusPartial discharge inception voltage-
dc.subject.keywordPlusPositive polarity-
dc.subject.keywordPlusThermal contraction-
dc.subject.keywordPlusVoltage characteristics-
dc.subject.keywordPlusPartial discharges-
dc.identifier.urlhttps://ieeexplore.ieee.org/document/8544729-
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > SCHOOL OF ELECTRICAL ENGINEERING > 1. Journal Articles