Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Prediction Model for the Carbonation of Post-Repair Materials in Carbonated RC Structures

Authors
Lee, Hyung-MinLee, Han-SeungSingh, Jitendra Kumar
Issue Date
May-2017
Publisher
MDPI AG
Keywords
carbonation; repair; prediction; post repair; carbonation depth; FEM analysis; FDM analysis
Citation
MATERIALS, v.10, no.5, pp.1 - 12
Indexed
SCIE
SCOPUS
Journal Title
MATERIALS
Volume
10
Number
5
Start Page
1
End Page
12
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/9663
DOI
10.3390/ma10050492
ISSN
1996-1944
Abstract
Concrete carbonation damages the passive film that surrounds reinforcement bars, resulting in their exposure to corrosion. Studies on the prediction of concrete carbonation are thus of great significance. The repair of pre-built reinforced concrete (RC) structures by methods such as remodeling was recently introduced. While many studies have been conducted on the progress of carbonation in newly constructed buildings and RC structures fitted with new repair materials, the prediction of post-repair carbonation has not been considered. In the present study, accelerated carbonation was carried out to investigate RC structures following surface layer repair, in order to determine the carbonation depth. To validate the obtained results, a second experiment was performed under the same conditions to determine the carbonation depth by the Finite Difference Method (FDM) and Finite Element Method (FEM). For the accelerated carbonation experiment, FDM and FEM analyses, produced very similar results, thus confirming that the carbonation depth in an RC structure after surface layer repair can be predicted with accuracy. The specimen repaired using inhibiting surface coating (ISC) had the highest carbonation penetration of 19.81, while this value was the lowest for the corrosion inhibiting mortar (IM) with 13.39 mm. In addition, the carbonation depth predicted by using the carbonation prediction formula after repair indicated that that the analytical and experimental values are almost identical if the initial concentration of Ca(OH)(2) is assumed to be 52%.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > MAJOR IN ARCHITECTURAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Han Seung photo

Lee, Han Seung
ERICA 공학대학 (MAJOR IN ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE