Evaluation of the iNtRON VRE vanA/vanB Real-Time PCR Assay for Detection of Vancomycin-Resistant Enterococci

Authors
Huh, Hee JaeJang, Mi-AeSeo, Ja YoungKim, Ji-YounKi, Chang-SeokKim, Jong-WonLee, Nam Yong
Issue Date
Jan-2015
Publisher
KOREAN SOC LABORATORY MEDICINE
Keywords
Real-time PCR; Performance; vanA; vanB; Vancomycin-resistant enterococci
Citation
ANNALS OF LABORATORY MEDICINE, v.35, no.1, pp.76 - 81
Journal Title
ANNALS OF LABORATORY MEDICINE
Volume
35
Number
1
Start Page
76
End Page
81
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/10907
DOI
10.3343/alm.2015.35.1.76
ISSN
2234-3806
Abstract
Background: Recently, the iNtRON VRE vanA/vanB real-time PCR (iNtRON; iNtRON Biotechnology, Korea) assay, a multiplex real-time PCR method, was introduced. In this prospective study, we compared the iNtRON assay with the Seep lex VRE ACE detection kit (Seep lex; Seegene, Korea), a conventional multiplex PCR assay. Methods: A chromogenic agar-based culture, in which pre-selected vancomycin-resistant enterococci (VRE) was grown and subsequently plated on blood agar with vancomycin disks, was regarded as the reference method. A total of 304 consecutive rectal swab specimens were tested for VRE by culture and by iNtRON and Seep lex PCR assays. For the PCR assays, specimens were enriched for 16-24 hr before PCR. Results: VRE were isolated from 44 (14.5%) specimens by chromogenic agar-based culture. The clinical sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the iNtRON assay were 100% (95% confidence interval: 89.8%-100%), 99.2% (96.9%-99.9%), 95.6% (83.6%-99.2%), and 100% (98.2%-100%), respectively, while those of the Seeplex assay were 97.7% (86.2%-99.9%), 99.6% (97.5%-99.9%), 97.7% (86.2%-99.9%), and 99.6% (97.5%-99.9%), respectively. The iNtRON assay had a detection limit of 3,159 copies/mu L and 13,702 copies/mu L for the vanA and vanB genes, respectively. No cross-reactivity was observed in 11 non-VRE bacterial culture isolates. Conclusions: The overall performance of the iNtRON assay was comparable to that of a chromogenic agar-based culture method for prompt identification of VRE-colonized patients in hospitals. This assay could be an alternative or supportive method for the effective control of nosocomial VRE infection.
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Seo, Ja Young photo

Seo, Ja Young
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE