Detailed Information

Cited 17 time in webofscience Cited 17 time in scopus
Metadata Downloads

Two-layer microdevice for parallel flow-through PCRs employing plastic syringes for semi-automated sample injection and a single heater for amplification: Toward process simplification and system miniaturization

Authors
Wu, WenmingLee, Nae Yoon
Issue Date
May-2013
Publisher
ELSEVIER SCIENCE SA
Keywords
Flow-through PCR; Poly(dimethylsiloxane); 3D spiral microchannel; Parallel reactions; Plastic disposable syringe; Semi-automated sample injection
Citation
SENSORS AND ACTUATORS B-CHEMICAL, v.181, pp.756 - 765
Journal Title
SENSORS AND ACTUATORS B-CHEMICAL
Volume
181
Start Page
756
End Page
765
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/14577
DOI
10.1016/j.snb.2013.02.062
ISSN
0925-4005
Abstract
This paper reports on the fabrication of a two-layer microdevice for conducting on-chip parallel flow-through polymerase chain reactions (PCRs) equipped with a single heater and disposable plastic syringes for semi-automated sample delivery for the construction of a portable PCR microdevice. Identical shapes of disconnected spiral-like microchannels were engraved on two poly(dimethylsiloxane) (PDMS) substrates having varying thicknesses, and by rotating either one of the substrates 180 degrees, they were aligned in such a way that one continuous sample flow was realized in a 3D configuration within a two-layer microdevice. Typical in vitro enzymatic amplifications were performed simultaneously in parallel on the microdevice by employing a single heater. Also, sample actuation module was miniaturized and its operation was semi-automated by employing portable plastic syringes as pumps. This system dispenses with the use of a bulky external apparatus such as a syringe pump, and also greatly simplifies the temperature control by utilizing a single heater, and therefore, downsizing the overall footprint of the device. Samples were injected into two inlets simultaneously and were successfully delivered through the entire length of the microchannels of over 2 m, mediated by portable plastic syringes. To investigate the feasibility of employing a single heater as well as to assess the reliability of the sample injection performance initiated by the plastic syringes, on-chip flow-through PCRs were performed using plasmid DNA as templates inside 2 m-long spiral microchannels constructed in a two-layer arrangement, as a proof-of-concept experiment. Target amplicons were successfully amplified simultaneously in parallel reactions inside the proposed microdevice in approximately 27 min with high reproducibility, confirming stable sample injection performance and reliable temperature control inside the microdevice. The proposed schemes could pave the way for device miniaturization, process simplification, and reaction parallelization, realizing a portable microfluidic device applicable for on-site and direct field uses. (c) 2013 Elsevier B.V. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
바이오나노대학 > 바이오나노학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Nae Yoon photo

Lee, Nae Yoon
BioNano Technology (Department of BioNano Technology)
Read more

Altmetrics

Total Views & Downloads

BROWSE