Breast Sonographic Elastography Using an Advanced Breast Tissue-Specific Imaging Preset Initial Clinical Results

Authors
Jung, Hyun JinHahn, Soo YeonChoi, Hye-YoungPark, Sung HeePark, Heung Kyu
Issue Date
Feb-2012
Publisher
AMER INST ULTRASOUND MEDICINE
Keywords
breast neoplasms; sonographic elastography; tissue characterization
Citation
JOURNAL OF ULTRASOUND IN MEDICINE, v.31, no.2, pp.273 - 280
Journal Title
JOURNAL OF ULTRASOUND IN MEDICINE
Volume
31
Number
2
Start Page
273
End Page
280
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/16606
DOI
10.7863/jum.2012.31.2.273
ISSN
0278-4297
Abstract
Objectives-The purpose of this study was to evaluate the interpretation criteria, such as the size ratio, stain ratio, and elasticity score, and to assess the diagnostic performance of sonographic elastography by using an advanced breast tissue-specific imaging preset compared with that of conventional sonography for the differentiation of benign and malignant breast masses. Methods-Conventional sonography and sonographic elastography with the tissue-specific imaging preset were performed in 104 patients (age range, 17-76 years; mean age, 47.7 years) with 110 breast lesions (67 benign and 43 malignant; mean size, 1.69 cm). The data from the interpretation criteria of sonographic elastography were obtained. The pathologic results from surgical excision or vacuum-assisted removal were used as a reference standard. Results-The values for the area under the receiver operating characteristic curve were 0.959 (95% confidence interval [CI], 0.902-0.987) for conventional sonography and 0.901 (95% CI, 0.829-0.949), 0.796 (95% CI, 0.708-0.866), and 0.787 (95% CI, 0.699-0.859) for the strain ratio, size ratio, and elasticity score, respectively. When a strain ratio cutoff point of 4.215 was used, the sensitivity and specificity were 86.0% and 85.1%. With a best cutoff point for conventional sonography between Breast Imaging Reporting and Data System categories 4A and 4B, the sensitivity and specificity were 93.0% and 83.6%. Conclusions-The strain ratio showed the best diagnostic performance among the interpretation criteria for sonographic elastography with the tissue-specific imaging preset. The diagnostic performance was slightly higher for Breast Imaging Reporting and Data System categories than for the strain ratio. However, there was no statistical significance (P = .052).
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles
교육대학원 > 교육학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Heung Kyu photo

Park, Heung Kyu
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE