Electrochemical Detection of C-Reactive Protein in Human Serum Based on Self-Assembled Monolayer-Modified Interdigitated Wave-Shaped Electrode
- Authors
- Chinnadayyala, Somasekhar R.; Park, Jinsoo; Kim, Young Hyo; Choi, Seong Hye; Lee, Sang-Myung; Cho, Won Woo; Lee, Ga-Yeon; Pyun, Jae-Chul; Cho, Sungbo
- Issue Date
- 2-Dec-2019
- Publisher
- MDPI
- Keywords
- interdigitated wave-shaped microelectrode array; self-assembled monolayer; C-reactive protein; immunosensor; atomic force microscopy; impedance spectroscopy
- Citation
- SENSORS, v.19, no.24
- Journal Title
- SENSORS
- Volume
- 19
- Number
- 24
- URI
- https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/26464
- DOI
- 10.3390/s19245560
- ISSN
- 1424-8220
- Abstract
- An electrochemical capacitance immunosensor based on an interdigitated wave-shaped micro electrode array (IDW mu E) for direct and label-free detection of C-reactive protein (CRP) was reported. A self-assembled monolayer (SAM) of dithiobis (succinimidyl propionate) (DTSP) was used to modify the electrode array for antibody immobilization. The SAM functionalized electrode array was characterized morphologically by atomic force microscopy (AFM) and energy dispersive X-ray spectroscopy (EDX). The nature of gold-sulfur interactions on SAM-treated electrode array was probed by X-ray photoelectron spectroscopy (XPS). The covalent linking of anti-CRP-antibodies onto the SAM modified electrode array was characterized morphologically through AFM, and electrochemically through cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The application of phosphate-buffered saline (PBS) and human serum(HS) samples containing different concentrations of CRP in the electrode array caused changes in the electrode interfacial capacitance upon CRP binding. CRP concentrations in PBS and HS were determined quantitatively by measuring the change in capacitance (Delta C) through EIS. The electrode immobilized with anti-CRP-antibodies showed an increase in Delta C with the addition of CRP concentrations over a range of 0.01-10,000 ng mL(-1). The electrode showed detection limits of 0.025 ng mL(-1) and 0.23 ng mL(-1) (S/N = 3) in PBS and HS, respectively. The biosensor showed a good reproducibility (relative standard deviation (RSD), 1.70%), repeatability (RSD, 1.95%), and adequate selectivity in presence of interferents towards CRP detection. The sensor also exhibited a significant storage stability of 2 weeks at 4 degrees C in 1 x PBS.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - IT융합대학 > 전자공학과 > 1. Journal Articles
![qrcode](https://api.qrserver.com/v1/create-qr-code/?size=55x55&data=https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/26464)
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.