Detailed Information

Cited 13 time in webofscience Cited 16 time in scopus
Metadata Downloads

Low-Tube-Voltage CT Urography Using Low-Concentration-Iodine Contrast Media and Iterative Reconstruction: A Multi-Institutional Randomized Controlled Trial. for Comparison with Conventional. CT Urography

Authors
Kim, Sang YounCho, Jeong YeonLee, JoongyubHwang, Sung IlMoon, Min HoanLee, Eun JuHong, Seong SookKim, Chan KyoKim, Kyeong AhPark, Sung BinSung, Deuk JaeKim, YongsooKim, You MeJung, Sung IlRha, Sung EunKim, Dong WonLee, HyunShim, YoungsupHwang, InpyeongWoo, SungminChoi, Hyuck Jae
Issue Date
Nov-2018
Publisher
KOREAN RADIOLOGICAL SOC
Keywords
Computed tomography; Low dose; Urography; Contrast media; Double dose reduction
Citation
KOREAN JOURNAL OF RADIOLOGY, v.19, no.6, pp.1119 - 1129
Journal Title
KOREAN JOURNAL OF RADIOLOGY
Volume
19
Number
6
Start Page
1119
End Page
1129
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/3141
DOI
10.3348/kjr.2018.19.6.1119
ISSN
1229-6929
Abstract
Objective: To compare the image quality of low-tube-voltage and low-iodine-concentration-contrast-medium (LVLC) computed tomography urography (CTU) with iterative reconstruction (IR) with that of conventional CTU. Materials and Methods: This prospective, multi-institutional, randomized controlled trial was performed at 16 hospitals using CT scanners from various vendors. Patients were randomly assigned to the following groups: 1) the LVLC-CTU (80 kVp and 240 mgI/mL) with IR group and 2) the conventional CTU (120 kVp and 350 mgI/mL) with filtered-back projection group. The overall diagnostic acceptability, sharpness, and noise were assessed. Additionally, the mean attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM) in the urinary tract were evaluated. Results: The study included 299 patients (LVLC-CTU group: 150 patients; conventional CTU group: 149 patients). The LVLC-CTU group had a significantly lower effective radiation dose (5.73 +/- 4.04 vs. 8.43 +/- 4.38 mSv) compared to the conventional CTU group. LVLC-CTU showed at least standard diagnostic acceptability (score >= 3), but it was non-inferior when compared to conventional CTU. The mean attenuation value, mean SNR, CNR, and FOM in all pre-defined segments of the urinary tract were significantly higher in the LVLC-CTU group than in the conventional CTU group. Conclusion: The diagnostic acceptability and quantitative image quality of LVLC-CTU with IR are not inferior to those of conventional CTU. Additionally, LVLC-CTU with IR is beneficial because both radiation exposure and total iodine load are reduced.
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Shim, Young Sup photo

Shim, Young Sup
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE