Abstract
Background and AimEndobiliary radiofrequency ablation (EB-RFA) is a new endoscopic palliation and adjunctive tool. Although EB-RFA is performed worldwide, a possibility of iatrogenic thermal injury leading to perforation or bleeding still remains. Therefore, we aimed to assess the effects of thermal and coagulation injury after in vivo EB-RFA using a new catheter with a temperature sensor in a swine model. MethodsTwelve mini pigs were divided into four groups according to power (33mm 10W electrode vs. 18mm 7W electrode) and RFA target temperature (75 degrees C vs. 80 degrees C). All mini pigs underwent endoscopic retrograde cholangiography and target temperature controlled EB-RFA for 120s. Additional cholangiogram was taken immediately after RFA, and all pigs were sacrificed after 24h to assess the macroscopic/microscopic RFA injury. ResultsMicroscopic maximal injury depth and ablation area of EB-RFA using a 33-mm 10W RFA electrode were significantly deeper and larger than those of EB-RFA using an 18-mm 7W electrode (median; 2.7 vs. 2.1mm, P=0.004, 48.9 vs. 36.2mm(2), P=0.016). However, there were no significant differences in microscopic ablation parameters between two different RFA target temperatures (75 degrees C vs. 80 degrees C). In addition, a post-RFA cholangiogram and assessment of the resected specimen at 24h after the RFA showed no adverse events such as perforation or bleeding. ConclusionsEB-RFA using a temperature controlled RFA catheter successfully ablates the bile duct wall without adverse events in a swine model.
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Yeon Suk photo

Kim, Yeon Suk
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE