Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

An accuracy analysis of tumor tracking algorithm according to types of respiration

Authors
Kim, W.S.Cho, J.K.Ahn, S.M.
Issue Date
2017
Publisher
Research India Publications
Keywords
Respiration type; Superior/Inferior Direction Error (SIDE); Treatment Targeting Error (TTE); Tumor tracking system
Citation
International Journal of Applied Engineering Research, v.12, no.24, pp.14064 - 14074
Journal Title
International Journal of Applied Engineering Research
Volume
12
Number
24
Start Page
14064
End Page
14074
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/6599
ISSN
0973-4562
Abstract
Purpose: In this study, derived type the optimal patient breathing through the precision analysis of tumor tracking algorithm in accordance with the respiratory type was applied to the Cyber-Knife SynchronyTM respiratory tumor tracking therapy. Methods: For the measurement, by End to End measurement method program of Cyber-Knife manufacturer using Dynamic Thorax and Gafchromic Film, Treatment Targeting Error (TTE) and Superior/Inferior Direction Error (SIDE) were analyzed at 90% and 95% dose thresholds, respectively. Results: 90% TTE in the Respiratory groupⅠ(regular) is 0.86±0.18 ~ 1.67±0.12, SIDE is -1.4±0.18 ~ -0.32±0.13, 95% error range of TTE is 1.05±0.19 ~ 2.34 ± 0.23, SIDE is -2.09±0.17 ~ 0.3±0.24. In the Respiration groupⅡ to stop (Hold) for aerobic respiration in 90% error range of TTE is 1.5±0.04 ~ 2.02±0.19, SIDE is -0.1±0.31 ~ 1.57±0.1. 95% error range of TTE is 1.31±0.13 ~ 2.33±0.13, SIDE is -0.05±0.34 ~ 1.67±0.2. In addition, in the Respiration groupⅢ (SI / RE) 90% error range of TTE is 1.29±0.39 ~ 2.32±0.24, SIDE is -1.31±0.18 ~ 1.2±0.21, 95% error range of TTE is 1.37±0.26 ~ 3.17±0.19, SIDE is -1.79±0.24 ~ 1.28±0.25. Conclusion: Patients should fully understand of the importance for a stable respiration and are well-informed of respiration prior to a 4-D CT scan and radiation therapy, and it is judged that it is very important to do tumor-tracking radiation therapy, After training them in respiration so that they come near to Respiration group through the advance respiratory training and have a stable respiration type. © Research India Publications.
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 방사선학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Ahn, Sung Min photo

Ahn, Sung Min
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE