Detailed Information

Cited 26 time in webofscience Cited 31 time in scopus
Metadata Downloads

Minimally invasive and continuous glucose monitoring sensor based on non-enzymatic porous platinum black-coated gold microneedles

Authors
Chinnadayyala, S.R.Park, JinsooSatti, A.T.Kim, DaeyoungCho, Sungbo
Issue Date
Feb-2021
Publisher
PERGAMON-ELSEVIER SCIENCE LTD
Keywords
Chronoamperometry; Electrochemical impedance spectroscopy; Electrodeposition; Interstitial fluid; Microelectromechanical systems; Microneedle electrode array
Citation
Electrochimica Acta, v.369
Journal Title
Electrochimica Acta
Volume
369
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/80382
DOI
10.1016/j.electacta.2020.137691
ISSN
0013-4686
Abstract
Individuals with diabetes can considerably benefit from continuous glucose monitoring (CGM). Addressing this challenge, a proof-of-concept for a pain-free CGM was presented based on a highly porous platinum black (Pt-black)-modified non-enzymatic microneedle electrode arrays (MNEAs). Porous Pt-black was electrodeposited on microneedle substrates using potentiometry by employing a charge density of -2.5 mA cm˗2. The surface of the porous Pt-black-modified microneedles (MNs) was optimally packed using Nafion (Nf) biocompatible ionomer. The dimensions of the fabricated microneedles were 650 µm × 110 µm × 150 µm in height, width, and thickness, respectively. The surface morphology of the modified MNs was studied using scanning electron microscopy (SEM) and energy dispersive X-ray analysis (EDX). The microneedle sensor showed a wide glucose dynamic range (1 − 20 mM) in phosphate buffer saline (PBS) and artificial interstitial fluid (ISF) in-vitro with good sensitivities (PBS: 5.786 µA mM−1 cm−2, ISF: 4.380 µA mM−1 cm−2), detection limits (PBS: 10 µM, ISF: 22.5 µM), stability (2% lost at the end of 7 h), selectivity, reproducibility (2.32% RSD), and a response time of 2 s with good glucose recoveries in ISF (98%-102.5%). The device exhibited good stability (7 days) as a sensor in-vivo and lost its functional activity after 7 days due to electrode biofouling. © 2020
Files in This Item
There are no files associated with this item.
Appears in
Collections
바이오나노대학 > 생명과학과 > 1. Journal Articles
IT융합대학 > 전자공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Somasekhar, Reddy Chinnadayyala photo

Somasekhar, Reddy Chinnadayyala
IT (Department of Electronic Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE