Detailed Information

Cited 8 time in webofscience Cited 8 time in scopus
Metadata Downloads

Comparison of remifentanil EC50 for facilitating i-gel and laryngeal mask airway insertion with propofol anesthesia

Authors
Choi, Jong BumKwak, Hyun JeongLee, Kyung CheonLee, Se RyeonLee, Sook YoungKim, Jong Yeop
Issue Date
Jun-2016
Publisher
SPRINGER JAPAN KK
Keywords
i-gel; Laryngeal mask airway; Remifentanil
Citation
JOURNAL OF ANESTHESIA, v.30, no.3, pp.377 - 383
Journal Title
JOURNAL OF ANESTHESIA
Volume
30
Number
3
Start Page
377
End Page
383
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/8239
DOI
10.1007/s00540-015-2133-6
ISSN
0913-8668
Abstract
Each supraglottic airway requires different anesthetic depth because it has a specific structure and different compressive force in the oropharyngeal cavity. We designed the study to compare the effect-site concentration (Ce) of remifentanil in 50 % of patients (EC50) for successful insertion of the i-gel second-generation supraglottic airway device with that for laryngeal mask airway (LMA) insertion during target-controlled infusion (TCI) of propofol. Forty-one female patients were randomized to the i-gel group (n = 20) or the LMA group (n = 21). Anesthesia was induced with propofol Ce of 5 mu g/ml and the predetermined remifentanil Ce, and the i-gel or LMA was inserted 5 min later. The remifentanil Ce was estimated by modified Dixon's up-and-down method (initial concentration: 3.0 ng/ml, step size: 0.5 ng/ml). The patient's response to device insertion was classified as either "success (no movement)" or "failure (movement)". Using the Dixon's up-and-down method, EC50 of remifentanil Ce for the i-gel (1.58 +/- 0.41 ng/ml) was significantly lower than that for LMA (2.25 +/- 0.55 ng/ml) (p = 0.038). Using isotonic regression, EC50 (83 % CI) of remifentanil in the i-gel group [1.50 (1.37-1.80) ng/ml] was statistically lower than that in the LMA group [2.00 (1.82-2.34) ng/ml]. EC95 (95 % CI) of remifentanil in the i-gel group [2.38 (1.48-2.50) ng/ml] was statistically lower than that in the LMA group [3.35 (2.58-3.48) ng/ml]. We found that EC50 of remifentanil Ce for i-gel insertion (1.58 ng/ml) was significantly lower than that for LMA insertion (2.25 ng/ml) in female patients during propofol TCI without neuromuscular blockade.
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kwak, Hyun Jeong photo

Kwak, Hyun Jeong
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE