Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Performance Evaluation of Deformable Image Registration Algorithms Using Computed Tomography of Multiple Lung Metastasesopen access

Authors
Han, Min CheolKim, JihunHong, Chae-SeonChang, Kyung HwanHan, Su ChulPark, KwangwooKim, Dong WookKim, HojinChang, Jee SukKim, JinaKye, SunsukPark, Ryeong HwangChung, YoonsunKim, Jin Sung
Issue Date
Feb-2022
Publisher
Adenine Press
Keywords
deformable image registration; lung deformation; tumor tracking; fiducial marker tracking; multiple lung metastases
Citation
Technology in Cancer Research and Treatment, v.21, pp 1 - 11
Pages
11
Indexed
SCIE
SCOPUS
Journal Title
Technology in Cancer Research and Treatment
Volume
21
Start Page
1
End Page
11
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/139487
DOI
10.1177/15330338221078464
ISSN
1533-0346
1533-0338
Abstract
Purpose: Various deformable image registration (DIR) methods have been used to evaluate organ deformations in 4-dimensional computed tomography (4D CT) images scanned during the respiratory motions of a patient. This study assesses the performance of 10 DIR algorithms using 4D CT images of 5 patients with fiducial markers (FMs) implanted during the postoperative radiosurgery of multiple lung metastases. Methods: To evaluate DIR algorithms, 4D CT images of 5 patients were used, and ground-truths of FMs and tumors were generated by physicians based on their medical expertise. The positions of FMs and tumors in each 4D CT phase image were determined using 10 DIR algorithms, and the deformed results were compared with ground-truth data. Results: The target registration errors (TREs) between the FM positions estimated by optical flow algorithms and the ground-truth ranged from 1.82 +/- 1.05 to 1.98 +/- 1.17 mm, which is within the uncertainty of the ground-truth position. Two algorithm groups, namely, optical flow and demons, were used to estimate tumor positions with TREs ranging from 1.29 +/- 1.21 to 1.78 +/- 1.75 mm. With respect to the deformed position for tumors, for the 2 DIR algorithm groups, the maximum differences of the deformed positions for gross tumor volume tracking were approximately 4.55 to 7.55 times higher than the mean differences. Errors caused by the aforementioned difference in the Hounsfield unit values were also observed. Conclusions: We quantitatively evaluated 10 DIR algorithms using 4D CT images of 5 patients and compared the results with ground-truth data. The optical flow algorithms showed reasonable FM-tracking results in patient 4D CT images. The iterative optical flow method delivered the best performance in this study. With respect to the tumor volume, the optical flow and demons algorithms delivered the best performance.
Files in This Item
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chung, Yoonsun photo

Chung, Yoonsun
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE