Detailed Information

Cited 1 time in webofscience Cited 0 time in scopus
Metadata Downloads

Development of paediatric mesh-type reference computational phantom series of International Commission on Radiological Protection

Authors
Choi, ChansooShin, BanghoYeom, Yeon SooNguyen, Thang TatHan, HaeginHa, SangseokChung, Beom SunBolch, Wesley E.Kim, Chan Hyeong
Issue Date
Sep-2021
Publisher
IOP PUBLISHING LTD
Keywords
ICRP Task Group 103; ICRP reference phantom; paediatric phantom; mesh-type; Monte Carlo simulation
Citation
Journal of Radiological Protection, v.41, no.3, pp.S160 - S170
Indexed
SCIE
SCOPUS
Journal Title
Journal of Radiological Protection
Volume
41
Number
3
Start Page
S160
End Page
S170
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/141096
DOI
10.1088/1361-6498/ac0801
ISSN
0952-4746
Abstract
Very recently, Task Group 103 of the International Commission on Radiological Protection (ICRP) completed the development of the paediatric mesh-type reference computational phantoms (MRCPs) comprising ten phantoms (newborn, one year-old, five year-old, ten year-old, and fifteen year-old males and females). The paediatric MRCPs address the limitations of ICRP Publication 143's paediatric reference computational phantoms, which are in voxel format, stemming from the nature of the voxel geometry and the limited voxel resolutions. The paediatric MRCPs were constructed by converting the voxel-type reference phantoms to a high-quality mesh format with substantial enhancements in the detailed anatomy of the small and complex organs and tissues (e.g. bones, lymphatic nodes, and extra-thoracic region). Besides, the paediatric MRCPs were developed in consideration of the intra-organ blood contents and by modelling the micron-thick target and source regions of the skin, lens, urinary bladder, alimentary tract organs, and respiratory tract organs prescribed by the ICRP. For external idealised exposures, the paediatric MRCPs provide very similar effective dose coefficients (DC(E)s) to those from the ICRP-143 phantoms but significantly different values for weakly penetrating radiations (e.g. the difference of similar to 20 000 times for 10 keV electron beams). This paper introduces the developed paediatric MRCPs with a brief explanation of the construction process. Then, it discusses their computational performance in Geant4, PHITS, and MCNP6 in terms of memory usage and computation speed and their impact on dose calculations by comparing their calculated values of DC(E)s for external exposures with those of the voxel-type reference phantoms.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE