Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

High voltage calibration method for the CMS RPC detector

Authors
Reyes-Almanza, R.Dimitrov, A.Fagot, A.Gul, M.Roskas, C.Tytgat, M.Zaganidis, N.Fonseca De Souza, S.Santoro, A.Da Silva De Araujo, F. TorresAleksandrov, A.Hadjiiska, R.Iaydjiev, P.Rodozov, M.Shopova, M.Sultanov, G.Litov, L.Pavlov, B.Petkov, P.Petrov, A.Qian, S. J.Han, D.Yi, W.Avila, C.Cabrera, A.Carrillo, C.Segura, M.Aly, S.Assran, Y.Mahrous, A.Mohamed, A.Combaret, C.Gouzevitch, M.Grenier, G.Lagarde, F.Laktineh, I. B.Mathez, H.Mirabito, L.Shchablo, K.Bagaturia, I.Lomidze, D.Lomidze, I.Pant, L. M.Bhatnagar, V.Gupta, R.Kumari, R.Lohan, M.Singh, J. B.Amoozegar, V.Boghrati, B.Ghasemy, H.Malmir, S.Najafabadi, M. MohammadiAbbrescia, M.Gelmi, A.Iaselli, G.Lezki, S.Pugliese, G.Benussi, L.Bianco, S.Piccolo, D.Primavera, F.Buontempo, S.Crescenzo, A.Galati, G.Fienga, F.Orso, I.Lista, L.Meola, S.Paolucci, P.Voevodina, E.Braghieri, A.Montagna, P.Ressegotti, M.Riccardi, C.Salvini, P.Vitulo, P.Cho, S. W.Choi, S. Y.Hong, B.Lee, K. S.Lim, J. H.Park, S. K.Goh, J.Kim, T. J.Carrillo Moreno, S.Miguel Colin, O.Vazquez Valencia, F.Carpinteyro Bernardino, S.Eysermans, J.Pedraza, I.Uribe Estrada, C.Duran-Osuna, M. C.Ramirez-Garcia, M.Ramirez-Sanchez, G.Sanchez-Hernandez, A.Rabadan-Trejo, R. I.Castilla-Valdez, H.Radi, A.Hoorani, H.Muhammad, S.Shah, M. A.Crotty, I.
Issue Date
Sep-2019
Publisher
IOP PUBLISHING LTD
Keywords
Detector alignment and calibration methods (lasers, sources, particle-beams); Performance of High Energy Physics Detectors; Resistive-plate chambers
Citation
JOURNAL OF INSTRUMENTATION, v.14, no.9, pp.1 - 8
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF INSTRUMENTATION
Volume
14
Number
9
Start Page
1
End Page
8
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/147258
DOI
10.1088/1748-0221/14/09/C09046
ISSN
1748-0221
Abstract
The Resistive Plate Chambers (RPC) are used for muon triggers in the CMS experiment. To calibrate the high voltage working-points (WP) and identify degraded detectors due to radiation or chemical damage, a high voltage scan has been performed using 2017 data from pp collisions at a center-of-mass energy of 13 TeV. In this paper, we present the calibration method and the latest results obtained for the 2017 data. A comparison with all scans taken since 2011 is considered to investigate the stability of the detector performance in time.
Files in This Item
Go to Link
Appears in
Collections
서울 자연과학대학 > 서울 물리학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Tae Jeong photo

Kim, Tae Jeong
COLLEGE OF NATURAL SCIENCES (DEPARTMENT OF PHYSICS)
Read more

Altmetrics

Total Views & Downloads

BROWSE