Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A baseline drift detrending technique for fast scan cyclic voltammetryopen access

Authors
DeWaele, MarkOh, YoonbaePark, CheonhoKang, Yu MinShin, HojinBlaha, Charles D.Bennet, Kevin E.Kim, In YoungLee, Kendall H.Jang, Dong Pyo
Issue Date
Nov-2017
Publisher
ROYAL SOC CHEMISTRY
Citation
ANALYST, v.142, no.22, pp.4317 - 4321
Indexed
SCIE
SCOPUS
Journal Title
ANALYST
Volume
142
Number
22
Start Page
4317
End Page
4321
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/151373
DOI
10.1039/c7an01465a
ISSN
0003-2654
Abstract
Fast scan cyclic voltammetry (FSCV) has been commonly used to measure extracellular neurotransmitter concentrations in the brain. Due to the unstable nature of the background currents inherent in FSCV measurements, analysis of FSCV data is limited to very short amounts of time using traditional background subtraction. In this paper, we propose the use of a zero-phase high pass filter (HPF) as the means to remove the background drift. Instead of the traditional method of low pass filtering across voltammograms to increase the signal to noise ratio, a HPF with a low cutoff frequency was applied to the temporal dataset at each voltage point to remove the background drift. As a result, the HPF utilizing cutoff frequencies between 0.001 Hz and 0.01 Hz could be effectively used to a set of FSCV data for removing the drifting patterns while preserving the temporal kinetics of the phasic dopamine response recorded in vivo. In addition, compared to a drift removal method using principal component analysis, this was found to be significantly more effective in reducing the drift (unpaired t-test p < 0.0001, t = 10.88) when applied to data collected from Tris buffer over 24 hours although a drift removal method using principal component analysis also showed the effective background drift reduction. The HPF was also applied to 5 hours of FSCV in vivo data. Electrically evoked dopamine peaks, observed in the nucleus accumbens, were clearly visible even without background subtraction. This technique provides a new, simple, and yet robust, approach to analyse FSCV data with an unstable background.
Files in This Item
Appears in
Collections
서울 의생명공학전문대학원 > 서울 의생명공학전문대학원 > 1. Journal Articles
서울 의과대학 > 서울 의공학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jang, Dong Pyo photo

Jang, Dong Pyo
GRADUATE SCHOOL OF BIOMEDICAL SCIENCE AND ENGINEERING (서울 생체의공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE