Acoustic lens for capacitive micromachined ultrasonic transducers
- Authors
- Chang, Chienliu; Firouzi, Kamyar; Park, Kwan Kyu; Sarioglu, Ali Fatih; Nikoozadeh, Amin; Yoon, Hyo-Seon; Vaithilingam, Srikant; Carver, Thomas; Khuri-Yakub, Butrus T.
- Issue Date
- Aug-2014
- Publisher
- IOP PUBLISHING LTD
- Keywords
- capacitive micromachined ultrasonic transducer (CMUT); acoustic lens; high intensity focused ultrasound (HIFU); poly-dimethylsiloxane (PDMS); focus; mold; bonding
- Citation
- JOURNAL OF MICROMECHANICS AND MICROENGINEERING, v.24, no.8, pp.1 - 14
- Indexed
- SCIE
SCOPUS
- Journal Title
- JOURNAL OF MICROMECHANICS AND MICROENGINEERING
- Volume
- 24
- Number
- 8
- Start Page
- 1
- End Page
- 14
- URI
- https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/159427
- DOI
- 10.1088/0960-1317/24/8/085007
- ISSN
- 0960-1317
- Abstract
- Capacitive micromachined ultrasonic transducers (CMUTs) have great potential to compete with traditional piezoelectric transducers in therapeutic ultrasound applications. In this paper we have designed, fabricated and developed an acoustic lens formed on the CMUT to mechanically focus ultrasound. The acoustic lens was designed based on the paraxial theory and made of silicone rubber for acoustic impedance matching and encapsulation. The CMUT was fabricated based on the local oxidation of silicon (LOCOS) and fusion-bonding. The fabricated CMUT was verified to behave like an electromechanical resonator in air and exhibited wideband response with a center frequency of 2.2 MHz in immersion. The fabrication for the acoustic lens contained two consecutive mold castings and directly formed on the surface of the CMUT. Applied with ac burst input voltages at the center frequency, the CMUT with the acoustic lens generated an output pressure of 1.89 MPa (peak-to-peak) at the focal point with an effective focal gain of 3.43 in immersion. Compared to the same CMUT without a lens, the CMUT with the acoustic lens demonstrated the ability to successfully focus ultrasound and provided a viable solution to the miniaturization of the multi-modality forward-looking endoscopes without electrical focusing.