Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

조적조 비내력벽을 가진 기존 학교 구조물의 내진 성능 평가Evaluation of Performance of Korean Existing School Buildings with Masonry Infilled Walls Against Earthquakes

Other Titles
Evaluation of Performance of Korean Existing School Buildings with Masonry Infilled Walls Against Earthquakes
Authors
문기훈전용률이창석한상환
Issue Date
Dec-2012
Publisher
한국지진공학회
Keywords
School structure; Seismic performance evaluation; Short column effect; Masonry infill wall; Shear failure; ATC 63
Citation
한국지진공학회논문집, v.16, no.6, pp.37 - 46
Indexed
KCI
Journal Title
한국지진공학회논문집
Volume
16
Number
6
Start Page
37
End Page
46
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/163909
DOI
10.5000/EESK.2012.16.6.037
ISSN
1226-525X
Abstract
In Korea, most existing school buildings have been constructed with moment frames with un-reinforced infill walls designed only considering gravity loads. Thus, the buildings may not perform satisfactorily during earthquakes expected in Korea. In exterior frames of the building, un-reinforced masonry infill walls with window openings are commonly placed, which may alter the structural behavior of adjacent columns due to the interaction between the wall and column. The objective of this study is to evaluate the seismic performance of existing school buildings according to the procedure specified in ATC 63. Analytical models are proposed to simulate the structural behavior of columns, infill walls and their interaction. The accuracy of the proposed model is verified by comparing the analytical results with the experimental test results for one bay frames with and without infill walls with openings. For seismic performance evaluation, three story buildings are considered as model frames located at sites having different soil conditions (S_A, S_B, S_C, S_D, S_E) in Korea. It is observed that columns behaves as a short columns governed by shear due to infill masonry walls with openings. The collapse probabilities of the frames under maximum considered earthquake ranges from 62.9 to 99.5 %, which far exceed the allowable value specified in ATC 63.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 건축공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Han, Sang Whan photo

Han, Sang Whan
COLLEGE OF ENGINEERING (SCHOOL OF ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE