부갑상선 기능 항진증에서 병변의 영상학적 진단과 위치 탐색 방법의 비교 연구Comparative Study of Preoperative Imaging Detection and Localization Test for Hyperparathyroidism
- Other Titles
- Comparative Study of Preoperative Imaging Detection and Localization Test for Hyperparathyroidism
- Authors
- 성의숙; 지용배; 최윤영; 김지영; 박정선; 이영준; 태경
- Issue Date
- Sep-2012
- Publisher
- 대한이비인후과학회
- Keywords
- Hyperparathyroidism; Localization; Parathyroidectomy; Ultrasonography; 99mTc-sestamibi scan
- Citation
- 대한이비인후과학회지 두경부외과학, v.55, no.9, pp.565 - 570
- Indexed
- KCI
- Journal Title
- 대한이비인후과학회지 두경부외과학
- Volume
- 55
- Number
- 9
- Start Page
- 565
- End Page
- 570
- URI
- https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/164700
- DOI
- 10.3342/kjorl-hns.2012.55.9.565
- ISSN
- 2092-5859
- Abstract
- Background and Objectives Accurate preoperative localization of abnormal parathyroid gland is essential for successful parathyroidectomy. The aim of this study was to evaluate the accuracy of a localization test for hyperparathyroidism including ultrasonography (US), computed tomography (CT) and 99mTc-sestamibi scan.
Subjects and Method We studied 47 patients with hyperparathyroidism who underwent parathyroidectomy from January 2003 through December 2010, retrospectively. 99mTc-sestamibi scan, US and CT were carried out as a preoperative localization test and their accuracy were analyzed according to the size, location and pathology of parathyroid lesions.
Results The accuracy of 99mTc-sestamibi scan, US and CT were 93%, 77% and 65%, respectively. The accuracy of 99mTc-sestamibi scan and CT combined was 94% and US and CT 73%. The accuracy of combination of US and 99mTc-sestamibi scan was 96%, which was not different depending on size, location and pathology of parathyroid lesions.
Conclusion The combination of 99mTc-sestamibi scan and US is the most effective method for preoperative detection and the localization of hyperparathyroidism.
- Files in This Item
-
Go to Link
- Appears in
Collections - 서울 의과대학 > 서울 이비인후과학교실 > 1. Journal Articles
- 서울 의과대학 > 서울 영상의학교실 > 1. Journal Articles
- 서울 의과대학 > 서울 핵의학교실 > 1. Journal Articles
![qrcode](https://api.qrserver.com/v1/create-qr-code/?size=55x55&data=https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/164700)
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.