Detailed Information

Cited 50 time in webofscience Cited 0 time in scopus
Metadata Downloads

Reliable and fast quantitative analysis of active ingredient in pharmaceutical suspension using Raman spectroscopy

Authors
Park, Seok ChanKim, MinjungNoh, JaegeunChung, HoeilWoo, YoungahLee, JonghwaKemper, Mark S.
Issue Date
Jun-2007
Publisher
ELSEVIER
Keywords
acetoaminophen; pharmaceutical suspension; Raman spectroscopy; wide area illumination; process analytical technology
Citation
ANALYTICA CHIMICA ACTA, v.593, no.1, pp.46 - 53
Indexed
SCIE
SCOPUS
Journal Title
ANALYTICA CHIMICA ACTA
Volume
593
Number
1
Start Page
46
End Page
53
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/172296
DOI
10.1016/j.aca.2007.04.056
ISSN
0003-2670
Abstract
The concentration of acetaminophen in a turbid pharmaceutical suspension has been measured successfully using Raman spectroscopy. The spectrometer was equipped with a large spot probe which enabled the coverage of a representative area during sampling. This wide area illumination (WAI) scheme (coverage area 28.3 mm(2)) for Raman data collection proved to be more reliable for the compositional determination of these pharmaceutical suspensions, especially when the samples were turbid. The reproducibility of measurement using the WAI scheme was compared to that of using a conventional small-spot scheme which employed a much smaller illumination area (about 100 mu m spot size). A layer of isobutyric anhydride was placed in front of the sample vials to correct the variation in the Raman intensity due to the fluctuation of laser power. Corrections were accomplished using the isolated carbonyl band of isobutyric anhydride. The acetaminophen concentrations of prediction samples were accurately estimated using a partial least squares (PLS) calibration model. The prediction accuracy was maintained even with changes in laser power. It was noted that the prediction performance was somewhat degraded for turbid suspensions with high acetaminophen contents. When comparing the results of reproducibility obtained with the WAI scheme and those obtained using the conventional scheme, it was concluded that the quantitative determination of the active pharmaceutical ingredient (API) in turbid suspensions is much improved when employing a larger laser coverage area. This is presumably due to the improvement in representative sampling.
Files in This Item
Go to Link
Appears in
Collections
서울 자연과학대학 > 서울 화학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Noh, Jae geun photo

Noh, Jae geun
COLLEGE OF NATURAL SCIENCES (DEPARTMENT OF CHEMISTRY)
Read more

Altmetrics

Total Views & Downloads

BROWSE