Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Selection of the optimal channel configuration for implementing wearable EEG devices for the diagnosis of mild cognitive impairmentopen access

Authors
Lee, KyeongguChoi, Kang-MinPark, SeonghunLee, Seung-HwanIm, Chang-Hwan
Issue Date
Nov-2022
Publisher
BMC
Keywords
Mild cognitive impairment; Electroencephalography; Wearable EEG device; Machine learning; Optimal channel configuration
Citation
ALZHEIMERS RESEARCH & THERAPY, v.14, no.1, pp.1 - 10
Indexed
SCIE
SCOPUS
Journal Title
ALZHEIMERS RESEARCH & THERAPY
Volume
14
Number
1
Start Page
1
End Page
10
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/172886
DOI
10.1186/s13195-022-01115-3
ISSN
1758-9193
Abstract
Background Early diagnosis of mild cognitive impairment (MCI) is essential for timely treatment planning. With recent advances in the wearable technology, interest has increasingly shifted toward computer-aided self-diagnosis of MCI using wearable electroencephalography (EEG) devices in daily life. However, no study so far has investigated the optimal electrode configurations for the efficient diagnosis of MCI while considering the design factors of wearable EEG devices. In this study, we aimed to determine the optimal channel configurations of wearable EEG devices for the computer-aided diagnosis of MCI. Method We employed an EEG dataset collected from 21 patients with MCI and 21 healthy control subjects. After evaluating the classification accuracies for all possible electrode configurations for the two-, four-, six-, and eight-electrode conditions using a support vector machine, the optimal electrode configurations that provide the highest diagnostic accuracy were suggested for each electrode condition. Results The highest classification accuracies of 74.04% +/- 4.82, 82.43% +/- 6.14, 86.28% +/- 2.81, and 86.85% +/- 4.97 were achieved for the optimal two-, four-, six-, and eight-electrode configurations, respectively, which demonstrated the possibility of precise machine-learning-based diagnosis of MCI with a limited number of EEG electrodes. Additionally, further simulations with the EEG dataset revealed that the optimal electrode configurations had significantly higher classification accuracies than commercial EEG devices with the same number of electrodes, which suggested the importance of electrode configuration optimization for wearable EEG devices based on clinical EEG datasets. Conclusions This study highlighted that the optimization of the electrode configuration, assuming the wearable EEG devices can potentially be utilized for daily life monitoring of MCI, is necessary to enhance the performance and portability.
Files in This Item
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Im, Chang Hwan photo

Im, Chang Hwan
COLLEGE OF ENGINEERING (서울 바이오메디컬공학전공)
Read more

Altmetrics

Total Views & Downloads

BROWSE