Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

MONTE CARLO CALCULATIONS OF NEUTRON DOSE CONVERSION COEFFICIENTS FOR REFERENCE KOREAN MALE

Authors
Kim, Chan HyeongJeong, Jong HwiCho, SungkooChoi, Sang HyounChung, Min Suk
Issue Date
Nov-2009
Publisher
TAYLOR & FRANCIS INC
Keywords
neutron dose; voxel model; Monte Carlo
Citation
NUCLEAR TECHNOLOGY, v.168, no.2, pp.345 - 348
Indexed
SCIE
SCOPUS
Journal Title
NUCLEAR TECHNOLOGY
Volume
168
Number
2
Start Page
345
End Page
348
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/175918
DOI
10.13182/NT09-A9206
ISSN
0029-5450
Abstract
Neutron fluence-to-organ dose conversion coefficients (DCCs) were calculated for a Reference Korean-adjusted male voxel model, HDRK-Man, for some standard irradiation geometries of external neutron beams using the Monte Carlo radiation transport code MCNPX. The calculated values were compared with those for other models. The results show that HDRK-Man provides consistent results for the DCC values considering the differences in the voxel models.