Growth and properties of new ZnSe(Al,O,Te) semiconductor scintillator

Authors
Lee, Woo GyoKim, Yong KyunKim, Jong-KyungStarzhinskiy, Nikolai G.Ryzhikov, VolodymyrGrinyov, Boris
Issue Date
Feb-2008
Publisher
PERGAMON-ELSEVIER SCIENCE LTD
Keywords
ZnSe; semiconductor scintillator; XRD; pulse height spectrum; afterglow
Citation
RADIATION MEASUREMENTS, v.43, no.2-6, pp.502 - 505
Indexed
SCIE
SCOPUS
Journal Title
RADIATION MEASUREMENTS
Volume
43
Number
2-6
Start Page
502
End Page
505
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/178988
DOI
10.1016/j.radmeas.2008.02.008
ISSN
1350-4487
Abstract
The zinc selenide crystals were grown in graphite crucibles by Bridgman-Stockbarger method in vertical compression furnace under argon pressure of 5 x 10(6) Pa. The grown ZnSe(Al,O,Te) single crystals were annealed in a Zn vapor at 1290K for 24h. An X-ray diffractometer (XRD) was used to investigate the structural properties of the zinc selenide single crystals. The lattice constants of the ZnSe single crystals were obtained from XRD data. After annealing it in a Zn vapor at 1290 K, it is found that the lattice constant decreases. From the absorption spectra, the band gap energies of the ZnSe single crystals were calculated by a linear fitting process. The band gap energy of the ZnSe(Al,O,Te) single crystal decreases more than that of the ZnSe single crystal. The maximum wavelength of the radioluminescence of the ZnSe(Al,O,Te) scintillator excited by X-ray was 606 nm, which was well matched with the response wavelength of the Si photodiode. The energy resolution of the annealed ZnSe(Al,O,Te) scintillator was 13.9% when it was exposed to (CS)-C-137 gamma-ray. Its size was 10 x 10 x 1 mm(3). The afterglow level of the annealed ZnSe(Al,O,Te) scintillator after 5 ms was 0.014%. The luminescence decay time of the annealed ZnSe(Al,O,Te) scintillator has two exponential components with 4 and 12 mu s time constants. The charged particle and the low energy gamma ray can be detected successfully with the annealed ZnSe(Al,O,Te) scintillator. It was investigated that the ZnSe(Al,O,Te) scintillator can be used for the security inspection system.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Yong Kyun photo

Kim, Yong Kyun
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE