Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Analysis of axial magnetic force distribution due to the axial clearance for electrical rotating machine

Authors
Kim, Ki ChanKoo, Dae HyunLee, Ju
Issue Date
Jun-2007
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Keywords
axial magnetic force; duct array; finite element method (FEM); reluctance torque
Citation
IEEE TRANSACTIONS ON MAGNETICS, v.43, no.6, pp.2546 - 2548
Indexed
SCIE
SCOPUS
Journal Title
IEEE TRANSACTIONS ON MAGNETICS
Volume
43
Number
6
Start Page
2546
End Page
2548
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/180056
DOI
10.1109/TMAG.2007.893303
ISSN
0018-9464
Abstract
This paper presents the study on the analysis method of axial force for general rotating machine having radial air-gap flux by axisymmetric 2-D finite element method (FEM). Axial force due to the gap in axial direction between stator and rotor causes damage to bearings, shaft and coupler. In order to use 2-D FEM, we propose some assumptions and a modeling method. The experiment by using measuring instrument on the shaft end is performed for the verification of analysis method. The minimizing axial force is also suggested by adjusting radial duct in the machine.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 전기공학전공 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Ju photo

Lee, Ju
COLLEGE OF ENGINEERING (MAJOR IN ELECTRICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE