STUDY ON CURE SHRINKAGE OF EMC USING DIELECTRIC SENSOR AND FBG SENSOR
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Baek, Jeong-Hyeon | - |
dc.contributor.author | Park, Dong-Woon | - |
dc.contributor.author | Park, Simon | - |
dc.contributor.author | Kim, Hak Sung | - |
dc.date.accessioned | 2023-05-03T09:38:48Z | - |
dc.date.available | 2023-05-03T09:38:48Z | - |
dc.date.created | 2023-04-06 | - |
dc.date.issued | 2022-06 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/184837 | - |
dc.description.abstract | The curing status and internal strain of epoxy molding compound (EMC) were monitored using a dielectric sensor and a fiber Bragg grating (FBG) sensor under curing conditions similar to the actual semiconductor packaging process. The dissipation factor was measured with a dielectric sensor during the molding process, and a gelation point, which is the starting point of effective cure shrinkage, was defined. Also, differential scanning calorimetry (DSC) test and rheometer test were performed and analyzed with dielectrometry measurement. In addition, Bragg wavelength (BW) was measured with the FBG sensor during the whole curing process and the cure shrinkage of the EMC was obtained. From these results, the effective cure shrinkage of the EMC that actually affects the residual stress of the EMC after curing processing was obtained. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | Composite Construction Laboratory (CCLab), Ecole Polytechnique Federale de Lausanne (EPFL) | - |
dc.title | STUDY ON CURE SHRINKAGE OF EMC USING DIELECTRIC SENSOR AND FBG SENSOR | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kim, Hak Sung | - |
dc.identifier.scopusid | 2-s2.0-85149180330 | - |
dc.identifier.bibliographicCitation | ECCM 2022 - Proceedings of the 20th European Conference on Composite Materials: Composites Meet Sustainability, v.1, pp.1557 - 1564 | - |
dc.relation.isPartOf | ECCM 2022 - Proceedings of the 20th European Conference on Composite Materials: Composites Meet Sustainability | - |
dc.citation.title | ECCM 2022 - Proceedings of the 20th European Conference on Composite Materials: Composites Meet Sustainability | - |
dc.citation.volume | 1 | - |
dc.citation.startPage | 1557 | - |
dc.citation.endPage | 1564 | - |
dc.type.rims | ART | - |
dc.type.docType | Conference Paper | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scopus | - |
dc.subject.keywordPlus | Curing | - |
dc.subject.keywordPlus | Dielectric devices | - |
dc.subject.keywordPlus | Electric sensing devices | - |
dc.subject.keywordPlus | Electromagnetic compatibility | - |
dc.subject.keywordPlus | Fiber Bragg gratings | - |
dc.subject.keywordPlus | Gelation | - |
dc.subject.keywordPlus | Molding | - |
dc.subject.keywordPlus | Shrinkage | - |
dc.subject.keywordPlus | Differential scanning calorimetry | - |
dc.subject.keywordPlus | A.Fibres | - |
dc.subject.keywordPlus | Cure shrinkage | - |
dc.subject.keywordPlus | Curing condition | - |
dc.subject.keywordPlus | Dielectric fibers | - |
dc.subject.keywordPlus | Dielectric sensors | - |
dc.subject.keywordPlus | Epoxy molding compounds | - |
dc.subject.keywordPlus | Fiber Bragg Grating Sensors | - |
dc.subject.keywordPlus | Gelation point | - |
dc.subject.keywordPlus | Internal strains | - |
dc.subject.keywordPlus | Semiconductor packaging | - |
dc.subject.keywordAuthor | Cure shrinkage | - |
dc.subject.keywordAuthor | Dielectric sensor | - |
dc.subject.keywordAuthor | EMC | - |
dc.subject.keywordAuthor | FBG sensor | - |
dc.subject.keywordAuthor | Gelation point | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.