Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Depiction of the Periosteum Using Ultrashort Echo Time Pulse Sequence with Three-Dimensional Cone Trajectory and Histologic Correlation in a Porcine Modelopen access

Authors
Kim, Dae JoongHwang, KunKim, HunCha, Jang GyJang, HyungseokPark, Ju-YongKim, Yeo Ju
Issue Date
Feb-2021
Publisher
KOREAN RADIOLOGICAL SOC
Keywords
UTE; Periosteum; 3D cone trajectory
Citation
KOREAN JOURNAL OF RADIOLOGY, v.22, no.5, pp.782 - 791
Indexed
SCIE
SCOPUS
KCI
Journal Title
KOREAN JOURNAL OF RADIOLOGY
Volume
22
Number
5
Start Page
782
End Page
791
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/189177
DOI
10.3348/kjr.2020.0640
ISSN
1229-6929
Abstract
Objective: To evaluate the signal intensity of the periosteum using ultrashort echo time pulse sequence with three-dimensional cone trajectory (3D UTE) with or without fat suppression (FS) to distinguish from artifacts in porcine tibias. Materials and Methods: The periosteum and overlying soft tissue of three porcine lower legs were partially peeled away from the tibial cortex. Another porcine tibia was prepared as three segments: with an intact periosteum outer and inner layer, with an intact periosteum inner layer, and without periosteum. Axial T1 weighted sequence (T1 WI) and 3D UTE (FS) were performed. Another porcine tibia without periosteum was prepared and subjected to 3D UTE (FS) and T1 WI twice, with positional changes. Two radiologists analyzed images to reach a consensus. Results: The three periosteal tissues that were partially peeled away from the cortex showed a high signal in 3D UTE (FS) and low signal on T1 WI. 3D UTE (FS) showed a high signal around the cortical surface with an intact outer and inner periosteum, and subtle high signals, mainly around the upper cortical surfaces with the inner layer of the periosteum and without periosteum. T1 WI showed no signal around the cortical surfaces, regardless of the periosteum state. The porcine tibia without periosteum showed changes in the high signal area around the cortical surface as the position changed in 3D UTE (FS). No signal was detected around the cortical surface in T1 WI, regardless of the position change. Conclusion: The periosteum showed a high signal in 3D UTE and 3D UTE FS that overlapped with artifacts around the cortical bone.
Files in This Item
Appears in
Collections
서울 의과대학 > 서울 영상의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Yeo Ju photo

Kim, Yeo Ju
COLLEGE OF MEDICINE (DEPARTMENT OF RADIOLOGY)
Read more

Altmetrics

Total Views & Downloads

BROWSE