Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

High-speed plasma diagnostics based on the floating harmonic method in inductively coupled plasma and pulsed plasma

Authors
Seo, Beom-JunKim, Kyung-HyunEo, HyundongLee, Ho-WonKim, Ju HoChung, Chin-Wook
Issue Date
Jul-2023
Publisher
IOP Publishing Ltd
Keywords
plasma; floating probe; diagnostic method; floating harmonic method; pulsed plasma; in-situ measurement; real-time measurement
Citation
PLASMA SOURCES SCIENCE & TECHNOLOGY, v.32, no.7, pp.1 - 15
Indexed
SCIE
SCOPUS
Journal Title
PLASMA SOURCES SCIENCE & TECHNOLOGY
Volume
32
Number
7
Start Page
1
End Page
15
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/189430
DOI
10.1088/1361-6595/acd9ed
ISSN
0963-0252
Abstract
The floating harmonic method is a diagnostic technique for obtaining plasma parameters, such as ion density and electron temperature, by applying a sinusoidal voltage to a floating probe. The typically applied frequency is in the kilohertz range. This method has been widely used in plasma diagnostics of semiconductor processes due to its robustness to RF fluctuations and fast measurement speed. However, recently, pulsed plasma has become common in semiconductor processes. As the plasma sheath is analyzed with a high-time-resolution diagnostic method such as phase-resolved optical emission spectroscopy, the development of high-speed plasma diagnostic techniques has become increasingly important. In this study, we investigated high-speed plasma diagnostic measurements based on the floating harmonic method. When the frequency of the voltage applied to the floating probe increases up to 1 MHz, the electron temperature can be underestimated due to the currents flowing through the capacitive sheath and the ceramic sleeve of the probe. We found that the displacement current of the probe sheath increases rapidly compared to the conduction current as the plasma density and electron temperature decrease. We also removed the additional harmonic currents flowing through the ceramic sleeve via two approaches. The plasma parameters obtained using the proposed method are in good agreement with the measurements performed using the floating harmonic method in the kilohertz range. Moreover, the electron temperature of the pulsed plasma was measured.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 전기공학전공 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chung, Chin Wook photo

Chung, Chin Wook
COLLEGE OF ENGINEERING (MAJOR IN ELECTRICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE