Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Long-term outcomes and predictors of adverse events of EUS-guided hepatico-gastrostomy for malignant biliary obstruction: Multicenter, retrospective study

Authors
Cho, Jae HeePark, Se WooKim, Eui JooPark, Chan HyukPark, Da HaeLee, Kyong JooLee, Sang Soo
Issue Date
Dec-2022
Publisher
SPRINGER
Keywords
Endoscopic ultrasound; Hepaticogastrostomy; Biliary obstruction; Risk factor; Stent
Citation
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, v.36, no.12, pp.8950 - 8958
Indexed
SCIE
SCOPUS
Journal Title
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES
Volume
36
Number
12
Start Page
8950
End Page
8958
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/191203
DOI
10.1007/s00464-022-09346-z
ISSN
0930-2794
Abstract
Background and Aims Endoscopic ultrasound (EUS)-guided hepaticogastrostomy (HGS) may be a feasible and useful alternative in patients with malignant biliary obstruction (MBO) after failed endoscopic retrograde cholangiopancreatography (ERCP). To date, the risk factors for adverse events (AEs) and long-term outcomes of EUS-HGS have not been fully explored according to stent type. Therefore, we evaluated potential risk factors for AEs and long-term outcomes of EUS-HGS. Methods In total, 120 patients who underwent EUS-HGS were retrospectively reviewed. A multivariate analysis through Cox proportional hazard and logistic regression model was used to identify the risk factors for stent dysfunction and AEs, respectively. Stent patency and patient survival were evaluated using Kaplan-Meier plots with a log-rank test for each stent. Results The technical and clinical success rates were 96.2% (102/106) and 83.0% (88/106). The median duration of stent patency was longer in self-expandable metal stents (SEMS) compared to plastic stents (PS) (158 vs. 108 days). Kaplan-Meier analysis indicated that the type of stent was not associated with stent patency (Hazard ratios [HR] 0.997, 95% confidence interval [CI] [0.525-1.896]) or overall survival. In addition, multivariate analysis indicated that hilar MBO significantly associated with stent dysfunction (HR, 2.340; 95% CI, 1.028-5.326, p = 0.043) and late AEs. Conclusions Given the lower incidence of AEs and better long-term outcomes of EUS-HGS, it can be considered a safe alternative to ERCP or percutaneous approaches regardless of which stent is used. Furthermore, hilar MBO was established as a potential risk factor for stent dysfunction and late AEs.
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 내과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Chan Hyuk photo

Park, Chan Hyuk
COLLEGE OF MEDICINE (DEPARTMENT OF INTERNAL MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE