Applicability of X-ray microscopy to non-contact tablet mass estimation
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Jiseok | - |
dc.contributor.author | Yim, Chewook | - |
dc.contributor.author | Kim, Yongkyun | - |
dc.date.accessioned | 2021-07-30T04:56:39Z | - |
dc.date.available | 2021-07-30T04:56:39Z | - |
dc.date.created | 2021-05-12 | - |
dc.date.issued | 2018-06 | - |
dc.identifier.issn | 0236-5731 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/2359 | - |
dc.description.abstract | The pharmaceutical tablet manufacturing process requires a tablet mass measuring step to ensure that all tablets have the prescribed dosage. The digital scales commonly used for that purpose require tens of seconds to stabilize, resulting in a substantial slow-down of the manufacturing process. The alternative visual approaches are fallible because of the potential existence of voids and cracks in the tablets. This paper uses an X-ray microscopy for mass measurement. Albeit with some constraints concerning tablet size and constituents, the approach can measure a tablet's mass in under one second, and may constitute, in the future, a viable and practical approach. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | SPRINGER | - |
dc.title | Applicability of X-ray microscopy to non-contact tablet mass estimation | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kim, Yongkyun | - |
dc.identifier.doi | 10.1007/s10967-018-5867-4 | - |
dc.identifier.scopusid | 2-s2.0-85046439256 | - |
dc.identifier.wosid | 000433200900015 | - |
dc.identifier.bibliographicCitation | JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, v.316, no.3, pp.1033 - 1038 | - |
dc.relation.isPartOf | JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY | - |
dc.citation.title | JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY | - |
dc.citation.volume | 316 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 1033 | - |
dc.citation.endPage | 1038 | - |
dc.type.rims | ART | - |
dc.type.docType | Article; Proceedings Paper | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalResearchArea | Nuclear Science & Technology | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Inorganic & Nuclear | - |
dc.relation.journalWebOfScienceCategory | Nuclear Science & Technology | - |
dc.subject.keywordPlus | PHARMACEUTICAL TABLETS | - |
dc.subject.keywordAuthor | Mass measurement | - |
dc.subject.keywordAuthor | Tablet manufacturing | - |
dc.subject.keywordAuthor | X-ray transmittance | - |
dc.subject.keywordAuthor | Imaging plate detector | - |
dc.subject.keywordAuthor | Volume measurement | - |
dc.identifier.url | https://link.springer.com/article/10.1007/s10967-018-5867-4 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.