Experimental validation of an effective carbon number-based approach for the gas chromatography-mass spectrometry quantification of 'compounds lacking authentic standards or surrogates'

Authors
Kim, Yong-HyunKim, Ki-HyunSzulejko, Jan E.Bae, Min-SukBrown, Richard J. C.
Issue Date
Jun-2014
Publisher
Elsevier BV
Keywords
Volatile organic compound; Carbon number; Effective carbon number; Sorbent tube; Thermal desorption; Gas chromatography/mass spectrometry applications
Citation
Analytica Chimica Acta, v.830, pp 32 - 41
Pages
10
Indexed
SCI
SCIE
SCOPUS
Journal Title
Analytica Chimica Acta
Volume
830
Start Page
32
End Page
41
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/25874
DOI
10.1016/j.aca.2014.04.052
ISSN
0003-2670
1873-4324
Abstract
For the quantitative analysis of 'compounds lacking authentic standards or surrogates' (CLASS) in environmental media, we previously introduced an effective carbon number (ECN) approach to develop an empirical equation for the prediction of their response factor (RF). In this research, a series of laboratory experiments were carried out to benchmark the reliability of an ECN approach for sorbent tube/thermal desorption/gas chromatography (GC)/mass spectrometry (MS) applications. First, the ECN values were determined using external calibration data from 25 reference volatile organic compounds (VOCs) using two MS dectectors (quadrupole (Q) and time-of-flight (TOF)). Then, a certified standard mixture of 54 VOCs was analyzed by each system as a simulated unknown sample. The analytical bias, assessed in terms of percentage difference (PD) between the certified and ECN-predicted mass values, averaged 19.2 ± 16.1% (TOF-MS) and 28.2 ± 27.6% (Q-MS). The bias using a more simplified carbon number (CN)-based prediction increased considerably, yielding 53.4 ± 53.3% (TOF-MS) and 61.7 ± 81.3% (Q-MS). However, the bias obtained using the ECN-based prediction decreased significantly to yield average PD values of 9.84 ± 7.28% (TOF-MS) and 16.8 ± 8.35% (Q-MS), if the comparison was limited to 26 (out of 54) VOCs with CN >= 4 (i.e., 25 aromatics and hexachlorobutadiene). (C) 2014 Elsevier B.V. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
서울 공과대학 > 서울 건설환경공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Ki Hyun photo

Kim, Ki Hyun
COLLEGE OF ENGINEERING (DEPARTMENT OF CIVIL AND ENVIRONMENTAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE